2011
DOI: 10.1248/yakushi.131.407
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Usefulness of Limited Sampling Strategies for Estimating AUC of Proton Pump Inhibitors

Abstract: Cytochrome P450 (CYP) 2C19 (CYP2C19) genotype is regarded as a useful tool to predict area under the blood concentration-time curve (AUC) of proton pump inhibitors (PPIs). In our results, however, CYP2C19 genotypes had no in‰uence on AUC of all PPIs during ‰uvoxamine treatment. Theseˆndings suggest that CYP2C19 genotyping is not always a good indicator for estimating AUC of PPIs. Limited sampling strategies (LSS) were developed to estimate AUC simply and accurately. It is important to minimize the number of bl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 35 publications
(27 reference statements)
0
6
0
Order By: Relevance
“…This study was unable to develop an acceptable omeprazole LSS model to estimate CL/F with NCA. These results add to the conflicting literature that support 5,17,18 and refute 19 the suitability of an omeprazole LSS approach. Differences in sample size, selection of omeprazole phenotyping parameter, and method of model validation exist among studies that may explain these conflicting findings.…”
Section: Discussionmentioning
confidence: 60%
See 4 more Smart Citations
“…This study was unable to develop an acceptable omeprazole LSS model to estimate CL/F with NCA. These results add to the conflicting literature that support 5,17,18 and refute 19 the suitability of an omeprazole LSS approach. Differences in sample size, selection of omeprazole phenotyping parameter, and method of model validation exist among studies that may explain these conflicting findings.…”
Section: Discussionmentioning
confidence: 60%
“…The selection of CL/F as a function of a partial AUC was done since omeprazole AUC currently lacks adequate validation, and using the AUC ratio of omeprazole to 5-hydroxyomeprazole has limited generalizability. Niioka reported three limited sampling models of plasma concentrations to estimate omeprazole AUC 5 . In a separate analysis of external data sets but using the same limited sampling models 5 , each model had bias and lacked precision 19 .…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations