2006
DOI: 10.2186/prp.5.214
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Usefulness of an Oral Moisture Checking Device (Mucus)

Abstract: A new oral moisture checking device (Mucus ® ) has been developed that can measure oral mucosal moisture within 2 seconds. The results of this study suggest that oral mucosal moisture can be measured with the new oral moisture checking device without any inter-operator error. AbstractPurpose: The aim of this study was to investigate the factors that may influence the results of measurements of oral mucosal moisture using the new oral moisture checking device, especially in relation to the operator and the sens… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(19 citation statements)
references
References 11 publications
0
19
0
Order By: Relevance
“…The usefulness and ease of use of this oral hygrometer (within 2 seconds) have been reported. 19,20 Following the manufacturer's definitions, oral moistness over 29% was considered normal, 25-29% was considered dry, and Ͻ 25% was considered severely dry. Each…”
Section: Study Protocolmentioning
confidence: 99%
“…The usefulness and ease of use of this oral hygrometer (within 2 seconds) have been reported. 19,20 Following the manufacturer's definitions, oral moistness over 29% was considered normal, 25-29% was considered dry, and Ͻ 25% was considered severely dry. Each…”
Section: Study Protocolmentioning
confidence: 99%
“…Table 2 shows the number and percentage of subjects with and without dry mouth according to the respective moisture measurements. In the group with dry mouth according to the moisturechecking device, the number of subjects with dry mouth according to the saliva wetness tester (13) was significantly higher than the number of subjects without dry mouth (1) (p < 0.01). In the group without dry mouth according to the moisture-checking device, the number of the subjects without dry mouth according to the saliva wetness tester (16) was significantly higher than the number of subjects with dry mouth (0) (p < 0.01).…”
Section: Resultsmentioning
confidence: 81%
“…Moisture measurements were usually performed in the lingual and buccal mucosa because many patients complain of dry mouth in those areas. In the present study, moisture measurements were performed only in the lingual mucosa according to the results of our previous study on the relationship between the lingual and buccal moisture levels and symptoms of dry mouth.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations