2020
DOI: 10.1080/02713683.2020.1737136
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Study on the Initial Experiences of French Vitreoretinal Surgeons with Heads-up Surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
26
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 24 publications
(32 citation statements)
references
References 27 publications
6
26
0
Order By: Relevance
“…Firstly, we found no differences in anatomical outcomes and postoperative BCVA gains between patients operated on with the NGENUITY System versus conventional microscopy in our study series. These results are in agreement with other study series 12 , 13 , 15 , 19 , 20 also demonstrating no differences in terms of safety or long-term visual prognosis when comparing the same techniques in vitrectomy surgery, and additionally for vitrectomy in the treatment of macular diseases 14 , 16 , 17 and RD 18 . Among the aforementioned studies, Zhang et al 20 , conducted the largest study on 23-gauge vitrectomy for the treatment of patients with vitreoretinal diseases in China.…”
Section: Discussionsupporting
confidence: 92%
See 3 more Smart Citations
“…Firstly, we found no differences in anatomical outcomes and postoperative BCVA gains between patients operated on with the NGENUITY System versus conventional microscopy in our study series. These results are in agreement with other study series 12 , 13 , 15 , 19 , 20 also demonstrating no differences in terms of safety or long-term visual prognosis when comparing the same techniques in vitrectomy surgery, and additionally for vitrectomy in the treatment of macular diseases 14 , 16 , 17 and RD 18 . Among the aforementioned studies, Zhang et al 20 , conducted the largest study on 23-gauge vitrectomy for the treatment of patients with vitreoretinal diseases in China.…”
Section: Discussionsupporting
confidence: 92%
“…The authors found no differences in final BCVA, anatomical findings, or outcomes among patients operated on with conventional microscopy compared to the NGENUITY System. Similarly, a very recent French study on a series of 180 vitrectomy surgeries for treatment of patients with RD and MH also found no significant differences between both techniques 19 .…”
Section: Discussionmentioning
confidence: 87%
See 2 more Smart Citations
“…Historically ophthalmic surgeons operated viewing through oculars of the operating microscope, creating surgeon movement restriction during surgery and spine problems due to ergonomic constraints of extended viewing at a microscope. Alcon (Ngenuity™) and Zeiss (Artevo™) have created digital head up displays for ophthalmic surgery to address these issues ( Eckardt and Paulo, 2016 ; Palacios et al, 2020 ). These digital viewing systems allow the surgeon more comfortably while operating and wearing 3D glasses to view surgery on a large monitor positioned beside the patient's surgical bed.…”
Section: Digital Technologymentioning
confidence: 99%