Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applicationsa)

Abstract: A clinical prototype of a scintillating fiber dosimeter array for quality assurance applications is presented. The array consists of a linear array of 29 plastic scintillation detectors embedded in a water-equivalent plastic sheet coupled to optical fibers used to guide optical photons to a charge coupled device (CCD) camera. The CCD is packaged in a light-tight, radiation-shielded housing designed for convenient transport. A custom designed connector is used to ensure reproducible mechanical positioning of th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
70
1

Year Published

2010
2010
2021
2021

Publication Types

Select...
8
1
1

Relationship

2
8

Authors

Journals

citations
Cited by 65 publications
(74 citation statements)
references
References 20 publications
3
70
1
Order By: Relevance
“…The PSD used in this study is composed of a 1 mm diameter by 1.0 (60.1) mm long polystyrene scintillating fiber (BCF-60, Saint-Gobain Crystals, Paris, France) for a total sensitive volume of 7.8 Â 10 À4 cm 3 , coupled with a polymethylmethacrylate Eska premier optical fiber 16 (Mitsubishi, Rayon Co., Ltd., Tokyo, Japan). Each single PSD is coated by a polyethylene jacket to increase the toughness of the detector.…”
Section: Iia1 Psdmentioning
confidence: 99%
“…The PSD used in this study is composed of a 1 mm diameter by 1.0 (60.1) mm long polystyrene scintillating fiber (BCF-60, Saint-Gobain Crystals, Paris, France) for a total sensitive volume of 7.8 Â 10 À4 cm 3 , coupled with a polymethylmethacrylate Eska premier optical fiber 16 (Mitsubishi, Rayon Co., Ltd., Tokyo, Japan). Each single PSD is coated by a polyethylene jacket to increase the toughness of the detector.…”
Section: Iia1 Psdmentioning
confidence: 99%
“…16,17 These consisted of 10 and 29 scintillation detectors arranged in a line. For external beam applications, the removal of the large Cerenkov background signal is essential.…”
Section: Iia Dosimeter Designmentioning
confidence: 99%
“…Scintillator detectors are also nearly water equivalent, unlike MOSFETs (metal oxide semiconductor field effect transistors) and diode detectors. Additionally, scintillator detectors are well known for their dose linearity and high spatial resolution (Beddar et al , 1992b, a; Fontbonne et al , 2002; Archambault et al , 2005; Beddar, 2006; Archambault et al , 2006; Lambert et al , 2007; Archambault et al , 2007; Lacroix et al , 2008)…”
Section: Discussionmentioning