2022
DOI: 10.1002/jper.21-0015
|View full text |Cite
|
Sign up to set email alerts
|

Clinical performance of hydrophilic, titanium‐zirconium dental implants in patients with well‐controlled and poorly controlled type 2 diabetes: One‐year results of a dual‐center cohort study

Jessica M. Latimer,
Katherine L. Roll,
Diane M. Daubert
et al.

Abstract: Background This study assessed the clinical performance of hydrophilic dental implants in a patient cohort with type 2 diabetes mellitus (T2DM). Methods Subjects with T2DM of ≥2‐years duration were allocated to either the well‐controlled (WC; HbA1c ≤ 7.0%,) or poorly‐controlled (PC; 7.5 < HbA1c < 10%) groups in a dual‐center, prospective cohort study. Each subject received a single, titanium‐zirconium (Ti‐Zr) dental implant with a chemically‐modified, hydrophilic (modSLA) surface in a posterior mandibular site… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 50 publications
0
8
0
Order By: Relevance
“…Diabetes can affect blood transport in the body, reduce the distribution of blood vessels in bone tissue, and increase the permeability of microcirculation capillaries. In turn, it affects the matrix composition and content around blood vessels and ultimately leads to delayed or nonunion of bone healing and even ischemic necrosis of bone in severe cases [ 26 ]. This work was to understand the effect of n-HA/PA66 material prepared in this experiment on bone defect healing of diabetic implants.…”
Section: Discussionmentioning
confidence: 99%
“…Diabetes can affect blood transport in the body, reduce the distribution of blood vessels in bone tissue, and increase the permeability of microcirculation capillaries. In turn, it affects the matrix composition and content around blood vessels and ultimately leads to delayed or nonunion of bone healing and even ischemic necrosis of bone in severe cases [ 26 ]. This work was to understand the effect of n-HA/PA66 material prepared in this experiment on bone defect healing of diabetic implants.…”
Section: Discussionmentioning
confidence: 99%
“…18 Both studies are based on an immediate-loaded implant placement technique. The results of the research from Aguilar et al, were supported by Latimer et al, 8 which was conducted for 1 year that dental implant survival reached 100% when the glycemic control was between >7.5%-10%. Other research reveals, when implant placement uses a minimally invasive approach and preventive augmentation procedures, it will result in good implant integration so that a high survival rate will be obtained.…”
Section: Implants Survival Rates Based On Hba1cmentioning
confidence: 81%
“…Histomorphometric results showed the highest BIC value were in implant surface modified with HA group, the highest new bone formation value in implant surface modified with SLA group, and increased osseointegration in both groups HA and SLA. 8,25 Therefore, implant surface modification with HA and SLA can be suggested in T2DM patients to enhance new bone formation and osseointegration.…”
Section: Implant Surface Modification and Implant Placement Technique...mentioning
confidence: 99%
See 1 more Smart Citation
“…Diabetic wound healing has been associated with a dysregulated M1 macrophage phenotype, while normal healing is associated with an M2 macrophage phenotype(Louiselle et al, 2021). However, implant therapy using titanium-zirconium dental implants with a SLActive surface treatment has been shown to be 100% successful in well-controlled and poorly controlled type two diabetes patients, although these studies have short clinical follow-up times(Cabrera-Domínguez et al, 2020;Latimer et al, 2022). Further studies are required to determine the clinical benefit dental implants with SLActive surface treatment may have in patients with diabetes and other medical conditions which may predispose patients toward an M1 macrophage phenotype during healing.5 | CONCLUSIONSConsidering the limitations within this systematic review, a differing macrophage inflammatory response to hydrophilic SLA surfaces compared to hydrophobic SLA on titanium or titanium-zirconium surfaces during in vitro studies is present.…”
mentioning
confidence: 99%