Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

9
108
1
2

Year Published

2007
2007
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 202 publications
(120 citation statements)
references
References 16 publications
9
108
1
2
Order By: Relevance
“…Our wear values compare well with those reported by others, with low wear rates for HCLPE liners after shortand medium-term followups (Table 2) [1,9,12,14,17,18,33,43]. However, the comparison of studies of wear reduction observed in HCLPE liners should be made with caution.…”
Section: Discussionsupporting
confidence: 90%
See 2 more Smart Citations
“…Our wear values compare well with those reported by others, with low wear rates for HCLPE liners after shortand medium-term followups (Table 2) [1,9,12,14,17,18,33,43]. However, the comparison of studies of wear reduction observed in HCLPE liners should be made with caution.…”
Section: Discussionsupporting
confidence: 90%
“…These clinically meaningful differences were calculated as follows. The mean annual wear measurements of eight HCLPE studies [1,9,12,14,17,18,33,43] (Table 2) were averaged. We presumed a meaningful difference would be the difference between this number and the mean annual wear of our control group generated from our historical cohort [21].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The acetabular abduction and anteversion angles were measured by one observer (JMM) as a component of the polyethylene wear analysis. The mean acetabular abduction angle and acetabular anteversion determined by the Martell method were 438 (range, 24°-58°) and 22°(range, 10°-39°), respectively [25][26][27].…”
Section: Methodsmentioning
confidence: 93%
“…Oxidation and subsequent embrittlement of UHMWPE decrease the abrasive wear resistance and increase the wear debris associated with the polymer [9,27,28,49]. Radiation crosslinking of UHMWPE reduces wear in vitro [48,50,51,53] and in vivo [29,47] but also induces free radicals, which can cause oxidation. Postirradiation melting renders crosslinked UHMWPE oxidation-resistant by allowing these residual free radicals trapped in the crystalline regions [8,40] to recombine.…”
Section: Introductionmentioning