Clinical Outcome of Dental Implants Placed with High Insertion Torques (Up to 176 Ncm)

Abstract: The use of high insertion torques (up to 176 Ncm) did not prevent osseointegration. Marginal bone levels in the control and experimental groups were similar both at the time of loading and 1 year later.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
82
1
5

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 57 publications
(97 citation statements)
references
References 32 publications
(113 reference statements)
2
82
1
5
Order By: Relevance
“…[5][6][7][8][9][10] Other authors reported that high insertion torque value is one of the main causes of marginal bone resorption 11 or, however, not necessary. [12][13][14][15] The aim of this article is to review the recent international literature about low and high implant insertion torque investigating their effects on marginal bone loss and implant survival rate.…”
mentioning
confidence: 99%
“…[5][6][7][8][9][10] Other authors reported that high insertion torque value is one of the main causes of marginal bone resorption 11 or, however, not necessary. [12][13][14][15] The aim of this article is to review the recent international literature about low and high implant insertion torque investigating their effects on marginal bone loss and implant survival rate.…”
mentioning
confidence: 99%
“…There is however very little evidence to support this assumption. Khayat and colleagues compared two groups of implants that were placed at standard and high insertion torque values and found no differences in terms of implant success and bone loss. Similarly, de Santes and colleagues found no correlation between high insertion torque values (>50 Ncm) and crestal bone loss after 3 years.…”
Section: Discussionmentioning
confidence: 99%
“…Despite the ability to accurately detect soft (type 4) bone via tactile feedback during osteotomy preparation, the soft bone surgical protocol was used in 45 implant sites with reportedly greater bone density. Placing a tapered implant into a slightly underprepared osteotomy has been advocated to improve primary stability in soft bone, but the technique may lead to high compression forces and elevated insertion torque values in bone with greater density . Concerns have been raised that such cases may impair local microcirculation, cause osteocyte necrosis, and result in bone resorption .…”
Section: Discussionmentioning
confidence: 99%