2016
DOI: 10.1186/s13019-016-0561-5
|View full text |Cite
|
Sign up to set email alerts
|

Clinical outcome and hemodynamic behavior of the Labcor Dokimos Plus aortic valve

Abstract: BackgroundThe Labcor Dokimos Plus (LDP) is a stented externally mounted pericardial aortic bioprosthesis, which was recently introduced in Europe. Aims of the study are evaluation of operative and postoperative results as well as hemodynamic performance.MethodsOne hundred consecutive patients with a mean age of 65.9 ± 10.7 years (range 35–87) and a mean EuroSCORE II of 3.1 ± 3.9 (range 0.67–24.5) underwent aortic valve replacement with the LDP. Mean valve-size was 25.2 ± 1.7 mm. Concomitant procedures were per… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 14 publications
0
4
0
Order By: Relevance
“…Out of 137 patients, 4 had moderate to severe paravalvular leakage that required reintervention. Another study that included 100 patients showed similar results in which no relevant central or paravalvular regurgitation was evident, and no structural or non-structural valve dysfunctions and no valve thrombosis were observed before discharge [ 10 ].…”
Section: Discussionmentioning
confidence: 89%
See 1 more Smart Citation
“…Out of 137 patients, 4 had moderate to severe paravalvular leakage that required reintervention. Another study that included 100 patients showed similar results in which no relevant central or paravalvular regurgitation was evident, and no structural or non-structural valve dysfunctions and no valve thrombosis were observed before discharge [ 10 ].…”
Section: Discussionmentioning
confidence: 89%
“…Prior studies assessed the performance of the Labcor Dokimos aortic valve postoperatively without short- or long-term follow-up [ 9 , 10 ]. In a single-centre study assessing the performance of the bioprosthesis, the haemodynamic results were satisfactory, i.e.…”
Section: Discussionmentioning
confidence: 99%
“…This minimizes leaflet and commissural stress, improving its effective orifice area (EOA) and leaflet movement, while reducing the risk of leaflet abrasion, stent deformation, and calcification. It allows for both intraanular and supraannular implantation and has achieved satisfactory performance and clinical outcomes comparable to other stented pericardial substitutes [20].…”
Section: Study Cohortmentioning
confidence: 92%
“…Previously, the stented bioprosthesis LDP showed excellent hemodynamic results, which are comparable to other contemporary stented pericardial valves like the Edwards Perimount Magna (Edwards Lifesciences, Irvine, CA, USA) and the St. Jude Trifecta (Medtronic Inc., Minneapolis, MN, USA). [4][5][6] Similarly, the stentless SFS showed …”
Section: Discussionmentioning
confidence: 99%
“…2,3) However, conventional stented bioprostheses have been constantly improved and the latest generation of these valves also impressed with their hemodynamic profile. [4][5][6] The Labcor Dokimos Plus (LDP) valve is one of these stented pericardial bioprosthesis with a low profile stent and externally mounted leaflets for the supraannular position. 7) Table 1 shows the geometric dimensions of both prostheses.…”
Section: Introductionmentioning
confidence: 99%