2020
DOI: 10.1093/ehjci/ehaa946.1390
|View full text |Cite
|
Sign up to set email alerts
|

Clinical implications of post-stent optical coherence tomographic findings after drug-eluting stent implantation: severe malapposition and thrombotic events

Abstract: Background The clinical implications of optical coherence tomography (OCT) assessment following percutaneous coronary intervention are controversial. Purpose We sought to evaluate the impact of post-stent OCT findings, including significant malapposition, on long-term clinical outcomes. Methods A total of 1,290 patients with 1,348 lesions, in which OCT was pe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Malapposed struts are more frequently uncovered at follow‐up, as compared with well‐apposed struts 14 . We found a numerically higher percentage of malapposed struts in the LUS group, immediately after stent implantation and at 3‐month follow‐up, with greater but clinically irrelevant malapposition areas and volumes 15 . However, the optimal stent deployment with an expansion index of 84% in both groups, achieved with contemporary implantation techniques assisted by OCT, has considerably reduced the number of US related to malapposition, to the point that only 14% of US in the LUS group were malapposed at 3 months, with a minimal malapposition area.…”
Section: Discussionmentioning
confidence: 63%
See 1 more Smart Citation
“…Malapposed struts are more frequently uncovered at follow‐up, as compared with well‐apposed struts 14 . We found a numerically higher percentage of malapposed struts in the LUS group, immediately after stent implantation and at 3‐month follow‐up, with greater but clinically irrelevant malapposition areas and volumes 15 . However, the optimal stent deployment with an expansion index of 84% in both groups, achieved with contemporary implantation techniques assisted by OCT, has considerably reduced the number of US related to malapposition, to the point that only 14% of US in the LUS group were malapposed at 3 months, with a minimal malapposition area.…”
Section: Discussionmentioning
confidence: 63%
“…14 We found a numerically higher percentage of malapposed struts in the LUS group, immediately after stent implantation and at 3-month follow-up, with greater but clinically irrelevant malapposition areas and volumes. 15 However, the optimal stent deployment with an expansion index of 84% in both groups, achieved with…”
Section: Us and Malappositionmentioning
confidence: 94%