Clinical, Experimental, and Computational Validation of a New Doppler-Based Index for Coarctation Severity Assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
31
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
3
1

Relationship

5
2

Authors

Journals

citations
Cited by 9 publications
(35 citation statements)
references
References 39 publications
2
31
0
Order By: Relevance
“…Rabbits were anesthetized and BP waveforms at the right carotid and femoral arteries were recorded simultaneously via uid-lled catheters 10 . Consistent with prior work, catheter-based measurements revealed mean BP remained near control levels despite coarctation severity 17 , likely due to the presence of collateral vessels [18][19][20] . Hence, a consistent mean BP was assumed temporally.…”
Section: Methodssupporting
confidence: 83%
See 1 more Smart Citation
“…Rabbits were anesthetized and BP waveforms at the right carotid and femoral arteries were recorded simultaneously via uid-lled catheters 10 . Consistent with prior work, catheter-based measurements revealed mean BP remained near control levels despite coarctation severity 17 , likely due to the presence of collateral vessels [18][19][20] . Hence, a consistent mean BP was assumed temporally.…”
Section: Methodssupporting
confidence: 83%
“…This allowed for the transfer of peak instantaneous Doppler gradient (PIDG) to corresponding catheter-based peak-instantaneous pressure gradient (PIBPG) i.e. PIDG = 1.76 PIBPG -6.9 17 based on data across a range of coarctation severities seen clinically. PIBPG for FSI simulations at younger ages was therefore calculated from weekly ultrasound data.…”
Section: Methodsmentioning
confidence: 99%
“…Isoflurane, but a recent study from our group using computational methods to implement simulated conscious hemodynamic conditions did not observe significant changes in velocity and BPG 11 . Values reported for thickness, contraction and relaxation from the preclinical CoA model were obtained ex vivo and not within an in vivo system where dynamic adjustments to HTN are being made.…”
Section: Discussionmentioning
confidence: 57%
“…Experimental procedures were approved by applicable Animal Care and Use Committees and conformed to the National Institutes of Health Guide for the Care and Use of Laboratory Animals. Briefly, New Zealand white rabbits (total 75; N=5-12/group) ~10 weeks old and weighing ~1.0 kg were anesthetized 11 and randomly designated to surgically undergo discrete CoA of varying severity and associated mechanical stimuli within the proximal descending thoracic aorta by tying suture around the aorta distal to the left subclavian branch against a wire of known diameter (1.6, 2.0 or 2.7 mm). CoA severity depended on diameter of the wire used, resulting in BPGpp within the clinical range (mild: ≤12, intermediate: [13][14][15][16][17][18][19], and severe: ≥20 mmHg).…”
Section: Preclinical Model Of Coamentioning
confidence: 99%
“…Figure 2C shows the best decision tree regression fit to contractile response from rabbit aortic tissue S1). BPGpp values have been converted from estimates via simplified Bernoulli equation to catheter representations using: Doppler gradient=1.62×BPGpp+21.33 from Ghorbannia et al 11 ‡Proximal and distal BP were measured under ≈1 MAC isoflurane after 22 wks using fluid-filled catheters advanced from carotid and femoral arteries to the aortic arch and descending thoracic aorta (diaphragm level), respectively.…”
Section: Preclinical Model Of Coamentioning
confidence: 99%