2014
DOI: 10.1016/j.prro.2013.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Clinical experience with 3-dimensional surface matching-based deep inspiration breath hold for left-sided breast cancer radiation therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
55
2

Year Published

2015
2015
2019
2019

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 53 publications
(61 citation statements)
references
References 11 publications
4
55
2
Order By: Relevance
“…Interfraction variability with DIBH has been reported, with characteristically higher treatment times early in RT courses, which likely reflects a DIBH "learning curve," which can be overcome quickly. 15,22 Differences in setup time or imaging were not recorded, but there were no adjustments to daily treatment schedules to accommodate DIBH patients and no uniform policy of filming patients differently based on treatment modality.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Interfraction variability with DIBH has been reported, with characteristically higher treatment times early in RT courses, which likely reflects a DIBH "learning curve," which can be overcome quickly. 15,22 Differences in setup time or imaging were not recorded, but there were no adjustments to daily treatment schedules to accommodate DIBH patients and no uniform policy of filming patients differently based on treatment modality.…”
Section: Discussionmentioning
confidence: 99%
“…Voluntary DIBH with AlignRT is reproducible with interfraction setup uncertainties of 0.7 to 2 mm. 22 In this light, voluntary DIBH is an accessible modality of DIBH that may be more comfortable and reproducible than ABC-DIBH.…”
Section: Discussionmentioning
confidence: 99%
“…Nevertheless, this is a reasonable assumption, given the goals of the analysis. Surface has been proven to be a reasonable surrogate for DIBH patient setup from a port film analysis in Tang et al (20) A total of 270 port films from 50 patients was analyzed to assess patient surface based setup accuracy. The distance between the field edge and the anterior pericardial shadow was measured on port films and corresponding digitally reconstructed radiographs (DRR).…”
Section: Discussionmentioning
confidence: 99%
“…However, there is always a certain level of motion and thus predetermined RTD tolerances (±3 mm and ± 3°) are used clinically. Our DIBH clinical planning guidelines can be found in Tang et al (20) …”
Section: Methodsmentioning
confidence: 99%
“…All of the patients reported in this study were lying supine on the slant board with no restraint. However, it has been reported that with use of a Vac‐Lok bag (Elekta Medical Intelligence, Atlanta, GA), the correlation coefficient between dDRR and dport is higher than for those without a Vac‐Lok bag, which leads to a reduced setup uncertainty (16) . Other studies also have reported that the use of cradles for breast patients can improve the reproducibility of the setup (17) …”
Section: Discussionmentioning
confidence: 99%