Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant retained overdentures

Abstract: BackgroundThis study was aimed to evaluate the influence of inter-implant distance on the wear characteristics of low-profile stud attachments used in mandibular implant retained overdentures.Material and MethodsForty Completely edentulous participants aged between 50 – 70 years were enrolled in this study. Each patient received 2-implants by 2-stage submerged surgical protocol. Participants categorized into 4-groups. Group I: 19 mm inter-implant distance with Locator retained overdentures; Group II: 19 mm int… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 33 publications
(41 reference statements)
0
3
0
Order By: Relevance
“…Split mouth study design was carried out previously to study implant behavior by applying different system in each quadrant [ 25 ]. The combined assessment by Locator ® and Equator® was designed based on the low-profile nature of both systems [ 26 ]. While both attachments are comparable in height [ 27 ], the variation of stud attachment height is tolerable within a limited range [ 28 , 29 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Split mouth study design was carried out previously to study implant behavior by applying different system in each quadrant [ 25 ]. The combined assessment by Locator ® and Equator® was designed based on the low-profile nature of both systems [ 26 ]. While both attachments are comparable in height [ 27 ], the variation of stud attachment height is tolerable within a limited range [ 28 , 29 ].…”
Section: Discussionmentioning
confidence: 99%
“…With advance of time, and due to the resiliency of the Locator ® and OT Equator ® , minute food debris accumulates to the intaglio of MIOD [ 32 ]. This movement is exaggerated with OT Equator ® due to loss of precision fit of nylon insert by wearing [ 26 ]. Adding to that, the day and night wearing of the overdenture after substitution of postinsertion complains.…”
Section: Discussionmentioning
confidence: 99%
“…The double retentive surface area is called "Dual retention" (internal and external features of the abutment) ensuring long-lasting retention life. (16,17) The T-Scan System is a dental device used to analyze the relative occlusal load that is recorded by a pressure mapping sensor intraorally. The system unit include computer software, recording sensor and handle assembly.…”
Section: Introductionmentioning