1980
DOI: 10.1136/hrt.43.2.202
|View full text |Cite
|
Sign up to set email alerts
|

Clinical evaluation of Dinamap 845 automated blood pressure recorder.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
36
0
1

Year Published

1982
1982
1999
1999

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 128 publications
(39 citation statements)
references
References 5 publications
2
36
0
1
Order By: Relevance
“…9 *" Arterial blood pressure was measured automatically every 2 minutes in the left arm with an oscillometric blood pressure recorder (Dinamap, Model 845, Critikon, Tampa, FL, USA). 12 The same values were found for blood pressure in the left arm and in the right arm. Heart rate (HR) was determined using a continuous electrocardiographic monitor (Electronics for Medicine, Honeywell, Pleasantville, NY, USA).…”
Section: Methodssupporting
confidence: 69%
See 1 more Smart Citation
“…9 *" Arterial blood pressure was measured automatically every 2 minutes in the left arm with an oscillometric blood pressure recorder (Dinamap, Model 845, Critikon, Tampa, FL, USA). 12 The same values were found for blood pressure in the left arm and in the right arm. Heart rate (HR) was determined using a continuous electrocardiographic monitor (Electronics for Medicine, Honeywell, Pleasantville, NY, USA).…”
Section: Methodssupporting
confidence: 69%
“…12 Interestingly, in previous studies 3 we observed that BA diameter was reduced after dihydralazine or cadralazine treatment, in contrast to the changes observed in response to other vasodilators, such as nitroglycerin or calcium inhibitors, which increased BA diameter. 4 Pharmacological research 1 ' 2 and previous studies from our laboratory 3 ' i have suggested that activation of the sympathetic nervous system leads to active vasoconstriction of the BA, in addition to inducing passive vasoconstriction following reduction in blood pressure.…”
mentioning
confidence: 80%
“…Blood pressure and heart rate were determined automatically, every minute, by an oscillometric recorder (Dynamap, model 845, Critikon, Tampa, Florida, USA) on the left arm. 25 Body fat distribution and endothelium G Arcaro et al…”
Section: Haemodynamic Evaluationsmentioning
confidence: 99%
“…After at least 20 minutes' rest in a room with constant temperature (23 卤 1掳C), the test was performed every time in basal condition and during an adrenergic stimulation (mental stress: consisting of complex mathematical calculations to execute in a short time period). Arterial pressure and heart rate were measured in the same times by means of a previously validated automatic device (Dinamap 845XT, Critikon, Johnson & Johnson, Tampa, FL, USA) [13].…”
Section: Methodsmentioning
confidence: 99%