Clinical assessment of image quality, usability and patient comfort in dedicated spiral breast computed tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 30 publications
1
3
0
1
Order By: Relevance
“…In addition, by post-processing the image data, iodine maps could be reconstructed, which allow conclusions to be drawn about contrast media uptake within the mammary gland tissue. In this way, breast carcinomas can be better recognized, assessed, and characterized in terms of their extent, similar to what has already been reported for the Dual-Energy EID CT 14 26 27 . Finally, no compression of the breast is required compared to mammography and, accordingly, a significantly higher level of patient comfort is provided 28 .…”
Section: Oncological Imagingsupporting
confidence: 72%
See 1 more Smart Citation
“…In addition, by post-processing the image data, iodine maps could be reconstructed, which allow conclusions to be drawn about contrast media uptake within the mammary gland tissue. In this way, breast carcinomas can be better recognized, assessed, and characterized in terms of their extent, similar to what has already been reported for the Dual-Energy EID CT 14 26 27 . Finally, no compression of the breast is required compared to mammography and, accordingly, a significantly higher level of patient comfort is provided 28 .…”
Section: Oncological Imagingsupporting
confidence: 72%
“…Darüber hinaus könnten durch Nachbearbeitung der Bilddaten Jodkarten rekonstruiert werden, welche Rückschlüsse auf die Kontrastmittelaufnahme innerhalb des Brustdrüsengewebes ermöglichen. Auf diese Weise können Mammakarzinome besser erkannt, hinsichtlich ihrer Ausdehnung beurteilt und charakterisiert werden, ähnlich wie dies bereits für das Dual-Energy EID-CT berichtet wurde [14,26,27]. Schlussendlich ist im Vergleich zur Mammographie keine Kompression der Brust erforderlich und dementsprechend ein deutlich höherer Patientenkomfort gegeben [28].…”
Section: Thorax Und Brustunclassified
“…This gantry setup bears the disadvantage that the axilla as well as the pectoralis muscle may not be sufficiently included in the field of view 137 . In a study comprising 1222 women, complete or almost complete breast coverage was reported in only 41.9% of the cases, whereas the pectoral muscle was not covered in 56.0% 138 . Wetzl et al 139 compared diagnostic confidence and detection rates of microcalcification in surgical specimen.…”
Section: Breast Ctmentioning
confidence: 99%
“… 137 In a study comprising 1222 women, complete or almost complete breast coverage was reported in only 41.9% of the cases, whereas the pectoral muscle was not covered in 56.0%. 138 Wetzl et al 139 compared diagnostic confidence and detection rates of microcalcification in surgical specimen. They concluded that BCT had a high sensitivity, specificity, and level of confidence, similar to digital breast tomosynthesis.…”
Section: Breast Ctmentioning
confidence: 99%
“…New generations of whole-body spectral CT systems obtain sourcegenerated spectral information from two (or more) scans at different energy levels (dual-energy), or detector-generated spectral response with layered and photon-counting (PC) detectors. The first breast CT scanners with PC detectors are being introduced in clinics (Kalender et al 2017, Berger et al 2019, Schmidt et al 2022) and synchrotron facilities (Longo et al 2016, where, in the latter case, tomography can be performed with low-energy (20-40 keV) monochromatic beams. Spectral CT imaging can improve tissue separation by acquiring data at multiple energy levels, allowing for spectral material decomposition analysis and the creation of e.g., virtual monochromatic images, iodine maps, and density-effective atomic number (ρ/Z eff ) maps.…”