2018
DOI: 10.4066/biomedicalresearch.29-18-138
|View full text |Cite
|
Sign up to set email alerts
|

Clinical application of triangular parabolic PEEK mesh with hole button produced by combining CAD, FEM and 3DP into cranioplasty

Abstract: Background: Cranioplasty (CP) helps to restore the integrity of the skull and the stability of the inner brain structure, to greatly improve the aesthetic and to reduce the concerns caused by the weakening of the brain's protection. However, how to achieve less complications while maintain a high aesthetic effect of CP has always been the pursuits of the neurosurgeons, manufactures and researchers.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 31 publications
(40 reference statements)
0
3
0
Order By: Relevance
“…Specifically, intervertebral devices ( n = 3), 27,28,42 spinal clips designed for spinal fusion infection ( n = 2) 30,31 and cylindrical implants ( n = 1) 29 were evaluated in these six studies. Furthermore, AM PEEK/PEKK was investigated for cranio‐maxillofacial (CMF) implants and reconstructions in six studies 4,6,40,49,56,58 . Mandibular implant ( n = 1), 6 cranial implants ( n = 2), 4,49 disk samples ( n = 1), 40 and porous scaffolds ( n = 2) 56,58 were printed in these six studies via both SLS and FFF.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Specifically, intervertebral devices ( n = 3), 27,28,42 spinal clips designed for spinal fusion infection ( n = 2) 30,31 and cylindrical implants ( n = 1) 29 were evaluated in these six studies. Furthermore, AM PEEK/PEKK was investigated for cranio‐maxillofacial (CMF) implants and reconstructions in six studies 4,6,40,49,56,58 . Mandibular implant ( n = 1), 6 cranial implants ( n = 2), 4,49 disk samples ( n = 1), 40 and porous scaffolds ( n = 2) 56,58 were printed in these six studies via both SLS and FFF.…”
Section: Resultsmentioning
confidence: 99%
“…Furthermore, AM PEEK/PEKK was investigated for cranio‐maxillofacial (CMF) implants and reconstructions in six studies 4,6,40,49,56,58 . Mandibular implant ( n = 1), 6 cranial implants ( n = 2), 4,49 disk samples ( n = 1), 40 and porous scaffolds ( n = 2) 56,58 were printed in these six studies via both SLS and FFF. In total, four studies investigated AM PAEKs for dental applications.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation