2021
DOI: 10.1053/j.jvca.2020.04.054
|View full text |Cite
|
Sign up to set email alerts
|

Clinical and Technical Limitations of Cerebral and Somatic Near-Infrared Spectroscopy as an Oxygenation Monitor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 139 publications
0
13
0
Order By: Relevance
“…It has shown promising results and is even the subject of clinical trials for this purpose. There are still technical limitations, not many NIRS devices are FDA approved, the current devices have shown limited reliability, and there are substantial differences in the obtained data across different NIRS devices ( Shaaban-Ali et al, 2021 ). However, as NIRS has been extensively studied in the last years, it can be expected to become more standardized and available for clinical practice.…”
Section: Discussionmentioning
confidence: 99%
“…It has shown promising results and is even the subject of clinical trials for this purpose. There are still technical limitations, not many NIRS devices are FDA approved, the current devices have shown limited reliability, and there are substantial differences in the obtained data across different NIRS devices ( Shaaban-Ali et al, 2021 ). However, as NIRS has been extensively studied in the last years, it can be expected to become more standardized and available for clinical practice.…”
Section: Discussionmentioning
confidence: 99%
“…Compared with NIRS and processed electroencephalography, monitoring with TCD is reusable as with any ultrasound machine. Newer NIRS modalities that can identify oxy and deoxy hemoglobin could represent an alternative to TCD in identifying the mechanism of brain desaturation 20 (Fig. 4).…”
Section: Discussionmentioning
confidence: 99%
“…NIRS is a new optical technique measuring blood oxygenation of the brain and detecting brain activities that emerged at the end of the last century. NIRS is a promising and reliable method for understanding human activities and is generally applied to the diagnosis and examination of brain diseases [ 54 , 55 ]. In 1977, Jobsis published his research findings in Science, proposing the utilization of the tissue permeability property of near-infrared light for the first time.…”
Section: Cerebral Blood Oxygen Saturation Monitoring Methodsmentioning
confidence: 99%
“…Along with the research progress in NIRS-based rSO 2 monitoring, many new types of monitoring equipment emerged, most of which are based on the above-mentioned principles. Although each has its own special technical features, NIRS-based rSO 2 monitoring equipment mainly utilizes three types of method: continuous wave spectroscopy (CWS), time-resolved spectroscopy (TRS), and frequency domain photon migration (FDPM) [ 10 , 55 ]. CWS is the most simple and reliable in terms of system function realization.…”
Section: Cerebral Blood Oxygen Saturation Monitoring Methodsmentioning