Aortic Valve 2011
DOI: 10.5772/24766
|View full text |Cite
|
Sign up to set email alerts
|

Clinical and Hemodynamic Performance of the Sorin Mitroflow Pericardial Bioprosthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…3 The Mitroflow aortic valve prosthesis (LivaNova, London, United Kingdom) was specifically designed to reduce flow obstruction by minimizing the size and thickness of the sewing ring and by placing the pericardial leaflet on the outside of the stent post to maximize the valve opening area. 4 Because of its intrinsic manufacturing characteristics, a Mitroflow valve prosthesis can be easily implanted where other pericardial valves of corresponding size might not fit or would require an annulus enlargement. 5 The implant technique does not differ from that used for any kind of standard stented prosthesis.…”
Section: Perspectivementioning
confidence: 99%
“…3 The Mitroflow aortic valve prosthesis (LivaNova, London, United Kingdom) was specifically designed to reduce flow obstruction by minimizing the size and thickness of the sewing ring and by placing the pericardial leaflet on the outside of the stent post to maximize the valve opening area. 4 Because of its intrinsic manufacturing characteristics, a Mitroflow valve prosthesis can be easily implanted where other pericardial valves of corresponding size might not fit or would require an annulus enlargement. 5 The implant technique does not differ from that used for any kind of standard stented prosthesis.…”
Section: Perspectivementioning
confidence: 99%
“…The Mitroflow LX is a variation of the A12 and had minor revisions such as the use of an automatic sewing machine, reduction of sewing ring seams to 1 seam, and prefixation by glutaraldehyde rather than postfixation. 18 Both Mitroflow A11/12 and Mitroflow LX do not undergo antimineralization treatment. The most recent modification, Mitroflow with phospholipid reduction therapy, added this step.…”
Section: Circulationmentioning
confidence: 99%
“…1 affect the design or performance of the prosthesis. 7 Therefore, both models can be considered the same bioprosthesis. 8 The major flaw of biological prostheses is the occurrence of structural valve deterioration (SVD) at mid or long term, which is variable depending on the type of prosthesis.…”
mentioning
confidence: 99%