Clinical and biophysical evaluation of variable bipolar configurations during radiofrequency ablation for treatment of ventricular arrhythmias

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
101
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 88 publications
(102 citation statements)
references
References 22 publications
0
101
1
Order By: Relevance
“…Standard unipolar radiofrequency ablation (RFA) is achieved between an ablation catheter tip and a ground patch placed on the body surface. Recent studies have demonstrated that bipolar ablation (bRFA), which uses two ablation catheter tips as active and ground poles, may produce larger and deeper lesions and more successfully ablate deeper midmyocardial circuits leading to ventricular arrhythmias (VAs) . In ex vivo studies, Nagashimi et al showed that bRFA between two irrigated‐tip catheters can create more transmural lesions, compared to sequential unipolar ablations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Standard unipolar radiofrequency ablation (RFA) is achieved between an ablation catheter tip and a ground patch placed on the body surface. Recent studies have demonstrated that bipolar ablation (bRFA), which uses two ablation catheter tips as active and ground poles, may produce larger and deeper lesions and more successfully ablate deeper midmyocardial circuits leading to ventricular arrhythmias (VAs) . In ex vivo studies, Nagashimi et al showed that bRFA between two irrigated‐tip catheters can create more transmural lesions, compared to sequential unipolar ablations.…”
Section: Introductionmentioning
confidence: 99%
“…In ex vivo studies, Nagashimi et al showed that bRFA between two irrigated‐tip catheters can create more transmural lesions, compared to sequential unipolar ablations. In a recent study, we have described optimal settings for ablation in the bipolar configuration, as well as reported on our experience with bRFA using two irrigated catheters for patients with midmyocardial VA circuits . Simultaneous ablation from a multipolar catheter has also been studied in ex vivo and in vivo models and shown to be more effective than focal sequential ablation …”
Section: Introductionmentioning
confidence: 99%
“…This study builds upon prior research into varying certain biophysical parameters to facilitate RF ablation . In this case, by altering environmental impedance, which is most pertinent for epicardial ablation, we demonstrate that RF ablation can be augmented.…”
Section: Discussionmentioning
confidence: 84%
“…27 Use of half-normal saline as the irrigant for open-irrigated RF ablation using a standard ablation catheter (ThermoCool SmartTouch or ThermoCool SF, Biosense Webster) was another nonstandard ablation approach employed. Bipolar ablation, as previously described, was performed using an ablation catheter on one side and a second ablation catheter on the opposing side of the myocardium (both 3.5-mm externally irrigated or 8-mm tip, Biosense Webster).…”
Section: Ablation Strategies and Endpointsmentioning
confidence: 99%
“…Other alternative techniques that we did not employ but that have been previously reported include transcoronary ethanol ablation, neuraxial modulation, and simultaneous unipolar ablation [35][36][37]. We used adjunctive techniques with which we had the most experience and which we had previously demonstrated success, although the decision about which adjunctive technique to use in a given case was operator-dependent and patient-specific, and future study comparing techniques with respect to procedural efficacy is warranted 27,28. In the present series, no single nonstandard technique was demonstrated to provide clear superiority in achieving ultimate success.…”