2020
DOI: 10.1093/ons/opaa398
|View full text |Cite|
|
Sign up to set email alerts
|

Clinical Accuracy, Technical Precision, and Workflow of the First in Human Use of an Augmented-Reality Head-Mounted Display Stereotactic Navigation System for Spine Surgery

Abstract: BACKGROUND Augmented reality mediated spine surgery is a novel technology for spine navigation. Benchmark cadaveric data have demonstrated high accuracy and precision leading to recent regulatory approval. Absence of respiratory motion in cadaveric studies may positively bias precision and accuracy results and analogous investigations are prudent in live clinical scenarios. OBJECTIVE To report a technical note, accuracy, prec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
46
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 72 publications
(54 citation statements)
references
References 33 publications
0
46
0
Order By: Relevance
“…A small number of solutions for AR-based intraoperative surgical guidance have been successfully demonstrated in humans, e.g., for spine [ 12 ] and hip [ 13 ] surgery. Nevertheless, AR has not been widely adopted and the vast majority of surgeries are still performed manually, without any computer-assisted aids.…”
Section: Introductionmentioning
confidence: 99%
“…A small number of solutions for AR-based intraoperative surgical guidance have been successfully demonstrated in humans, e.g., for spine [ 12 ] and hip [ 13 ] surgery. Nevertheless, AR has not been widely adopted and the vast majority of surgeries are still performed manually, without any computer-assisted aids.…”
Section: Introductionmentioning
confidence: 99%
“…5,6 However, in patients, the same ARHMD system enabled 100% accuracy for pedicle screw placement, although this was only for 6 screws placed in 1 patient. 7 It also was shown to provide excellent clinical accuracy for osteotomies, discectomies, and pedicle screw placement during posterior en bloc L1 corpectomy for a chordoma. 8 A different AR system was used for percutaneous pedicle screw placement during transforaminal lumbar interbody fusion with 94% accuracy; however, this system relies on remote displays and does not use a head-mounted AR display.…”
Section: Discussionmentioning
confidence: 99%
“…That is, we did not determine whether these screws were placed exactly where the surgeon intended them to be placed. The precision of this particular ARHMD system has been examined previously in both cadavers and patients, 6,7 and as our institution's experience with ARHMD-guided surgery increases, we are keenly interested in determining both the accuracy and precision of pedicle screws placed using AR on a larger number of patients and among multiple surgeons.…”
Section: Limitationsmentioning
confidence: 99%
See 1 more Smart Citation
“…5 Although AR displays are used to show stereotactic information such as pedicle screw trajectories, current AR systems do not dynamically interact with the surgeon and the environment, and any performance metric is derived from imaging studies evaluating the outcome of the AR system. 49 This is a serious limitation to the current status of AR for surgeon performance improvement. AR systems could display relevant case information, metrics, distances, force measurements, etc., that would be automatically collected and analyzed, which would provide peerless assessments of technical skill in a true operative setting.…”
Section: Augmented Realitymentioning