2009
DOI: 10.1016/j.ijrobp.2008.12.041
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log Files

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

15
308
2
8

Year Published

2014
2014
2018
2018

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 305 publications
(333 citation statements)
references
References 18 publications
15
308
2
8
Order By: Relevance
“…The accuracy of the correlation model has been evaluated in a previous publication 14. The mean correlation model errors were less than 0.3 mm in their study, indicating that use of the correlation model to predict the tumor position is reliable.…”
Section: Methodsmentioning
confidence: 90%
“…The accuracy of the correlation model has been evaluated in a previous publication 14. The mean correlation model errors were less than 0.3 mm in their study, indicating that use of the correlation model to predict the tumor position is reliable.…”
Section: Methodsmentioning
confidence: 90%
“…We assumed that the motion of a lung tumor occurs in this direction, and the infrared marker on the abdomen was used to estimate tumor motion. Because the major axis of tumor motion inside the patient is in the SI direction rather than in AP or LR directions, the synchrony system reduces tracking errors (16) . However, directions and amplitudes of the motion of normal tumors in the lung or liver differ in absolute terms from those of the chest and abdomen.…”
Section: Discussionmentioning
confidence: 99%
“…The system includes the Synchrony Respiratory Tracking System v.9.6, which makes real‐time adjustments to the robotic arm position to follow the moving target 15 , 16 , 17 . The target locating system (TLS) is composed of two ceiling‐mounted diagnostic X‐ray sources paired with amorphous silicon detectors, and acquires live digital radiographic images of the target, bony anatomy, and fiducial markers.…”
Section: Methodsmentioning
confidence: 99%
“…Patient respiration is a particular challenge for treatment sites such as the lung and liver 2 . Imaging‐based respiratory motion compensation strategies generally use kilo‐voltage x‐rays and often assume correlation between external surrogates and internal motion 3 , 4 . Ultrasound has been explored for use in both inter‐ and intra‐fraction motion compensation strategies and its use in RT has recently been reviewed 5 .…”
Section: Introductionmentioning
confidence: 99%