Abstract:The Compact Linear Collider (CLIC) is a proposed future electron-positron collider, designed to perform collisions at energies from 0.5 to 5 TeV, with a nominal design optimized for 3 TeV (Dannheim, 2012). CLIC generates three beams: the drive beam, the main electron beam and the positron beam. The drive beam is a high current electron beam that is accelerated in an S-band linac and then decelerated in 12 GHz structures to generate the RF for accelerating the colliding main electron and positron beams. The dri… Show more
“…The CLIC gun needs to generate a 143us long current pulse to feed the accelerator. A review of the CLIC gun design was performed by SLAC [1]. In this follow-on report, the key parameters of the grid pulser were derived from the review report.…”
Section: Pulser Parameters and Analysismentioning
confidence: 99%
“…Some parameters of the pulser are directly related to the CLIC Thermionic Gun Requirements. Therefore, Table 1 is cited below from the gun design report [1]. Parameters passed directly to the pulser are highlighted.…”
Section: Pulse Width Repetition Rate and Floating Deck Voltagementioning
confidence: 99%
“…The electron gun design proposed in the report [1] is similar to CID gun in SLAC [2]. SLAC CID gun pulser can deliver up to 300V pulse into a 50 Ohm load for a maximum length of 5us.…”
Section: Slac Cid Gun Pulsermentioning
confidence: 99%
“…Pulser current and floating deck configurationGrid interception current and delivered current are investigated in the gun design report.Figure 8in the report[1] is cited below.…”
“…The CLIC gun needs to generate a 143us long current pulse to feed the accelerator. A review of the CLIC gun design was performed by SLAC [1]. In this follow-on report, the key parameters of the grid pulser were derived from the review report.…”
Section: Pulser Parameters and Analysismentioning
confidence: 99%
“…Some parameters of the pulser are directly related to the CLIC Thermionic Gun Requirements. Therefore, Table 1 is cited below from the gun design report [1]. Parameters passed directly to the pulser are highlighted.…”
Section: Pulse Width Repetition Rate and Floating Deck Voltagementioning
confidence: 99%
“…The electron gun design proposed in the report [1] is similar to CID gun in SLAC [2]. SLAC CID gun pulser can deliver up to 300V pulse into a 50 Ohm load for a maximum length of 5us.…”
Section: Slac Cid Gun Pulsermentioning
confidence: 99%
“…Pulser current and floating deck configurationGrid interception current and delivered current are investigated in the gun design report.Figure 8in the report[1] is cited below.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.