Abstract:Sufficient supplies were purchased to test ten explosives using the NOL Card Gap Test as described in Department of the Army Technical Bulletin TB 700-2 (Explosives Hazard Classification Procedures) dated • 19•May 1967. A calibration series was. fi~ed using pressed TNT (den-sity= 1.626 Mg/m3). The estimated 50% point was 158 cards.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.