2007
DOI: 10.1016/j.ndteint.2007.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Circular discontinuities detection in welded joints using Circular Hough Transform

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…By carrying out the line profile diametrically at full width half maximum (FWHM), the diameter was estimated as 16.25 ± 0.25 mm and the calibrated pixel size was 0.25 mm. Hence, the diameter obtained by the automatic sizing approach using the area gave a closer estimate to the actual size of the object in comparison to the estimate made by the line profile and perimeter [19] .…”
Section: Sizing Of Circular Featuresmentioning
confidence: 72%
See 1 more Smart Citation
“…By carrying out the line profile diametrically at full width half maximum (FWHM), the diameter was estimated as 16.25 ± 0.25 mm and the calibrated pixel size was 0.25 mm. Hence, the diameter obtained by the automatic sizing approach using the area gave a closer estimate to the actual size of the object in comparison to the estimate made by the line profile and perimeter [19] .…”
Section: Sizing Of Circular Featuresmentioning
confidence: 72%
“…Yazid et al [19] described the application of a separability mask and the circular Hough transform (CHT) to the detection of circular objects in radiographic images of weld joints where the success rate was 81.82%, which indicated that their system was suitable for the detection of circular features in the weld zone. In the present paper, the Hough transform is used to isolate circular-shaped pores, which appear as rounded indications on the radiographs of the tube-to-tube weld joints of the steam generators of a prototype fast breeder reactor (PFBR).…”
Section: Introductionmentioning
confidence: 99%
“…Many methods have been suggested for identifying the round objects. Circular Hough transform (CHT), which proposed by Duda et al [ 27 ], is one of the most successful method [ 28 ] for detection of round objects on the images. In this study, CHT operations are used for candidate nodule detection.…”
Section: Architecture Of the Computer-aided Pipelinementioning
confidence: 99%
“…In the medical field itself, another application is classification and localization of diabetic related eyes diseases. Other applications include detection of car wheels, detection of cross-section of composite yarn, aorta detection in ultra sound pictures, atom structure detection and various other industrial applications [1].…”
Section: Introductionmentioning
confidence: 99%