Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005.
DOI: 10.1109/ias.2005.1518439
|View full text |Cite
|
Sign up to set email alerts
|

Circuit breaker concepts for future high-power DC-applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
109
0

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 207 publications
(109 citation statements)
references
References 4 publications
0
109
0
Order By: Relevance
“…This huge power loss occurs during the on-state conduction because the resistance of the new solid state DC breakers is negligibly small. Though the cost of the new solid state breakers seems prohibitive, in reality it is not so, because the fast switching of the IGBT provides excellent protection against the internal converter faults and short-circuit on the DC transmission network whose cost are relatively high.Further comparisons of the DC breakers based on various voltages are shown in [5]. From table 1 and 2, we find that the solid-state CB are cheaper compared to other four types of DC breakers and have the ability for fast switching operation.…”
Section: Comparison Of the DC Circuit Breakers Topologiesmentioning
confidence: 94%
See 1 more Smart Citation
“…This huge power loss occurs during the on-state conduction because the resistance of the new solid state DC breakers is negligibly small. Though the cost of the new solid state breakers seems prohibitive, in reality it is not so, because the fast switching of the IGBT provides excellent protection against the internal converter faults and short-circuit on the DC transmission network whose cost are relatively high.Further comparisons of the DC breakers based on various voltages are shown in [5]. From table 1 and 2, we find that the solid-state CB are cheaper compared to other four types of DC breakers and have the ability for fast switching operation.…”
Section: Comparison Of the DC Circuit Breakers Topologiesmentioning
confidence: 94%
“…In a multi-terminal system with large wind power integration, a fault on one converter can be cascaded to other converter stations; consequently a fast DC breaker is necessary to protect the VSC-HVDC system. To avert the damage it is important to use an HVDC circuit breaker that can quickly isolate the faulty section from the system [5]. VSC-HVDC system utilizes Insulated Gate Bipolar Transistors (IGBT) for fast switching purposes.…”
Section: Introductionmentioning
confidence: 99%
“…In order to maintain the reliability of supply system, the fault should be cleared within a few milliseconds. In this regard, numerous HVDC circuit breaker (CB) designs have been reported in the literature [21], [22]- [25]. The HVDC CBs are classified into two categories namely, solid state CB and the hybrid CB.…”
Section: B High Voltage Switchgearmentioning
confidence: 99%
“…Using HVDC circuit breakers to interrupt and isolate a DC fault has been discussed in literature, such as in [6][7][8][9][10] and industrial DC circuit breaker prototypes are being produced [7,11,12]. A Fault Current Limiter (FCL) may be used to limit the fault current the DC circuit breaker needs to interrupt.…”
Section: Introductionmentioning
confidence: 99%