2021
DOI: 10.3390/diagnostics11091700
|View full text |Cite
|
Sign up to set email alerts
|

Ciliary Videomicroscopy: A Long Beat from the European Respiratory Society Guidelines to the Recognition as a Confirmatory Test for Primary Ciliary Dyskinesia

Abstract: Primary ciliary dyskinesia (PCD) is a rare inherited ciliopathy in which respiratory cilia are stationary or dyskinetic. The clinical presentation of PCD is highly non-specific since it includes infections and disorders of the upper (otitis and rhinosinusitis) and lower (neonatal respiratory distress, bronchitis, pneumonia and bronchiectasis) airways, starting in early life. Clinical examination alone does not allow a PCD diagnosis, which relies on several concordant tests, since none are sensitive or specific… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 59 publications
(85 reference statements)
0
10
0
Order By: Relevance
“…Mateos-Quiros et al, 2021;Mikhailik et al, 2021;Reula et al, 2021;Smith et al, 2012;Zahid et al, 2020). The lack of a standardized fps for imaging motile cilia is especially problematic because it hinders high-speed video microscopy from being clinically adapted as a diagnostic tool to help uncover motile cilia diseases, such as primary ciliary dyskinesia (Bricmont et al, 2021;Shapiro et al, 2018). The large disparity in frame rates used to image cilia motility is partly technology dependant, with early studies generally being restricted to lower fps imaging technology (2-25 Hz) (Clary-Meinesz et al, 1992;Hennessy et al, 1986), while more recent studies with access to much faster and cheaper imaging technology generally having higher fps (≥500 fps) (Smith et al, 2012;Yasuda et al, 2020).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Mateos-Quiros et al, 2021;Mikhailik et al, 2021;Reula et al, 2021;Smith et al, 2012;Zahid et al, 2020). The lack of a standardized fps for imaging motile cilia is especially problematic because it hinders high-speed video microscopy from being clinically adapted as a diagnostic tool to help uncover motile cilia diseases, such as primary ciliary dyskinesia (Bricmont et al, 2021;Shapiro et al, 2018). The large disparity in frame rates used to image cilia motility is partly technology dependant, with early studies generally being restricted to lower fps imaging technology (2-25 Hz) (Clary-Meinesz et al, 1992;Hennessy et al, 1986), while more recent studies with access to much faster and cheaper imaging technology generally having higher fps (≥500 fps) (Smith et al, 2012;Yasuda et al, 2020).…”
Section: Discussionmentioning
confidence: 99%
“…However, no standardized frame rate exists when imaging cilia motility for subsequent CBF calculation, this has resulted in a large range of frames rates used to image cilia motility within the published literature (Abdelhamed et al, 2018 ; Abdelhamed et al, 2020 ; Bustamante‐Marin et al, 2019 ; Chen et al, 2016 ; Hagiwara et al, 2020 ; Hennessy et al, 1986 ; Liu et al, 2021 ; Mateos‐Quiros et al, 2021 ; Mikhailik et al, 2021 ; Reula et al, 2021 ; Smith et al, 2012 ; Zahid et al, 2020 ). The lack of a standardized fps for imaging motile cilia is especially problematic because it hinders high‐speed video microscopy from being clinically adapted as a diagnostic tool to help uncover motile cilia diseases, such as primary ciliary dyskinesia (Bricmont et al, 2021 ; Shapiro et al, 2018 ). The large disparity in frame rates used to image cilia motility is partly technology dependant, with early studies generally being restricted to lower fps imaging technology (2–25 Hz) (Clary‐Meinesz et al, 1992 ; Hennessy et al, 1986 ), while more recent studies with access to much faster and cheaper imaging technology generally having higher fps (≥500 fps) (Smith et al, 2012 ; Yasuda et al, 2020 ).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…HSVA is a technique that uses light microscopy to observe respiratory cilia ex vivo and a high-speed video camera to record them [46]. Ciliary beat frequency (CBF), ciliary beat pattern (CBP), and effective mucociliary clearance are all measured in recorded videos [47]. As a diagnostic tool, HSVA allows the ciliary function to be tested on the same day [48].…”
Section: High-speed Video Microscopy Analysis (Hsva)mentioning
confidence: 99%
“…The CBF is the only quantitative observable being routinely determined in diagnostic centers. Even though the conventional HSVM approach is commonly considered as the most sensitive and specific test to identify PCD, its lack of standardisation prevents its use as a confirmatory diagnostic test, or its inclusion in a diagnostic algorithm [5].…”
Section: Introductionmentioning
confidence: 99%