2012
DOI: 10.1186/2046-2530-1-14
|View full text |Cite
|
Sign up to set email alerts
|

ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software

Abstract: BackgroundAnalysis of ciliary function for assessment of patients suspected of primary ciliary dyskinesia (PCD) and for research studies of respiratory and ependymal cilia requires assessment of both ciliary beat pattern and beat frequency. While direct measurement of beat frequency from high-speed video recordings is the most accurate and reproducible technique it is extremely time consuming. The aim of this study was to develop a freely available automated method of ciliary beat frequency analysis from digit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

3
73
1
2

Year Published

2014
2014
2019
2019

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 83 publications
(87 citation statements)
references
References 19 publications
3
73
1
2
Order By: Relevance
“…Automated software CiliaFA was used, which runs on opensource software (ImageJ) (Smith et al, 2012). The software extracts the pixel intensities of the region of interest (ROI) over time from previously recorded video.…”
Section: Organotypic Tissue Culture Modelsmentioning
confidence: 99%
“…Automated software CiliaFA was used, which runs on opensource software (ImageJ) (Smith et al, 2012). The software extracts the pixel intensities of the region of interest (ROI) over time from previously recorded video.…”
Section: Organotypic Tissue Culture Modelsmentioning
confidence: 99%
“…Cell cultures (at the w5 time point only) were visualized using an Axiovert 200 M microscope (Carl Zeiss, Germany) connected to a Sony XCD V60 Firewire camera. A total 256 images of the cultures were recorded per insert, and CBF was then calculated using Cilia FA software as described by Smith et al 61 Each condition was tested in triplicate on four independent occasions (n = 4).…”
mentioning
confidence: 99%
“…Several groups have attempted to overcome these problems by developing software to automate analysis from the digital images [53][54][55].…”
Section: Page 5 Of 36mentioning
confidence: 99%
“…Although assessment of ciliary function by light microscopy is recognised as a critical diagnostic test used as 'first-line' in many centres [11,17,48,53,54,56] it should be noted that some clinicians question its value and recommend that HVMA should be reserved for research purposes [20]. A limitation of HVMA is the need for specialist equipment, rigorous quality control and experienced technicians with a high through-put of normal and abnormal samples.…”
Section: Page 5 Of 36mentioning
confidence: 99%