2020
DOI: 10.1186/s12984-020-00720-3
|View full text |Cite
|
Sign up to set email alerts
|

Chronic nerve health following implantation of femoral nerve cuff electrodes

Abstract: Background Peripheral nerve stimulation with implanted nerve cuff electrodes can restore standing, stepping and other functions to individuals with spinal cord injury (SCI). We performed the first study to evaluate the clinical electrodiagnostic changes due to electrode implantation acutely, chronic presence on the nerve peri- and post-operatively, and long-term delivery of electrical stimulation. Methods A man with bilateral lower extremity paralysis secondary to cervi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
16
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(19 citation statements)
references
References 85 publications
3
16
0
Order By: Relevance
“…However, the absence of large changes to recruitment order in the contacts tested is consistent with the interpretation that these changes in threshold were not likely due to significant movement of the cuff. Such changes in charge thresholds postoperatively agree with the results of our previous study which demonstrated an acute increase in charge thresholds postoperatively with a maximum at two months before their return to near baseline at six months. Differences in activation thresholds for muscles within a single contact tended to increase over the four‐month period, although these changes only minimally affected the recruitment order, which indicates that they were likely produced by differences in fascicle‐to‐contact distance and encapsulation that could serve to increase requisite charge.…”
Section: Discussionsupporting
confidence: 92%
See 3 more Smart Citations
“…However, the absence of large changes to recruitment order in the contacts tested is consistent with the interpretation that these changes in threshold were not likely due to significant movement of the cuff. Such changes in charge thresholds postoperatively agree with the results of our previous study which demonstrated an acute increase in charge thresholds postoperatively with a maximum at two months before their return to near baseline at six months. Differences in activation thresholds for muscles within a single contact tended to increase over the four‐month period, although these changes only minimally affected the recruitment order, which indicates that they were likely produced by differences in fascicle‐to‐contact distance and encapsulation that could serve to increase requisite charge.…”
Section: Discussionsupporting
confidence: 92%
“…In the setting of an AIS C classification, these changes demonstrate a preservation of the subject's preoperative functional and clinical neuromuscular health. This investigation complements our previous study, which documented changes to similar parameters in a subject with femoral nerve C‐FINEs implanted in the vicinity of the inguinal ligament .…”
Section: Discussionsupporting
confidence: 87%
See 2 more Smart Citations
“…The C-FINEs ( Figure 2) consist of thin layers of flexible silicone elastomer sandwiching a narrow layer of polyether ether keytone (PEEK) polymer stiffening bar with an array of platinum contacts on the top and bottom of the cuff. This configuration has been shown to gently reshape the nerve into an elongated oval [23] which allows individual contacts along the width of the nerve to selectively access different fascicles with minimal to no effect on nerve health [24], [25].…”
Section: A Multi-contact Electrode Implantationmentioning
confidence: 99%