1998
DOI: 10.1021/ed075p1599
|View full text |Cite
|
Sign up to set email alerts
|

Chromatography, Absorption, and Fluorescence: A New Instrumental Analysis Experiment on the Measurement of Polycyclic Aromatic Hydrocarbons in Cigarette Smoke

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0
2

Year Published

2000
2000
2014
2014

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(14 citation statements)
references
References 15 publications
(22 reference statements)
0
12
0
2
Order By: Relevance
“…Tobacco smoke deposits were dissolved in a 1:1 mixture of methanol:methylene chloride. For BaP measurements the samples were filtered using a 0.2 µm Acrodisc CR (Gelman Sciences, Ann Arbor, MI) then evaporated to dry- 38 Recovery rates for spiked Pallflex filter samples and the hollow tracheobronchial airway model were similar and averaged 60.8 ± 1.7%. The recovery rate was low because of the multiple sequential containers that were required because of sample size requirements and because UVPM and BaP were measured from each sample.…”
Section: Model Preparationmentioning
confidence: 99%
“…Tobacco smoke deposits were dissolved in a 1:1 mixture of methanol:methylene chloride. For BaP measurements the samples were filtered using a 0.2 µm Acrodisc CR (Gelman Sciences, Ann Arbor, MI) then evaporated to dry- 38 Recovery rates for spiked Pallflex filter samples and the hollow tracheobronchial airway model were similar and averaged 60.8 ± 1.7%. The recovery rate was low because of the multiple sequential containers that were required because of sample size requirements and because UVPM and BaP were measured from each sample.…”
Section: Model Preparationmentioning
confidence: 99%
“…Analysis of PAHs in TPM has been achieved by two major instrumental methods: high pressure liquid chromatography with fluorimetric detection (HPLC-FD) (15,(26)(27)(28) and gas chromatography-mass spectrometry (GC-MS) selective ion monitoring (SIM) mode analysis (16)(17)(18). Gas chromatography-flame ionization detection (GC-FID) and GC-MS have been employed for PAH analysis in gas phase of MSS (18,19).…”
Section: Determination Of Pahs In Mssmentioning
confidence: 99%
“…These included gas chromatography [2,3], high-performance liquid chromatography (HPLC) [4][5][6] and hyphenated methods such as gas chromatography-mass spectrometry (GC-MS) [4,[5][6][7][8][9][10][11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%