Handbook of Oil Spill Science and Technology 2014
DOI: 10.1002/9781118989982.ch5
|View full text |Cite
|
Sign up to set email alerts
|

Chromatographic Fingerprinting Analysis of Crude Oils and Petroleum Products

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
7
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 125 publications
2
7
0
Order By: Relevance
“…The densities of Location 1 and Location 2 with values of 0.8448 g/ml and 0.8227 g/ml fall within the range of 0.78-0.88 g/ml listed for light crude oils while the density of the co-mingled sample from Location 3 with a value of 0.9012 falls with the range (0.88 g/ml-10 g/ml) of crude oils designated as heavy. The density values recorded for these three crude samples agree with 0.8400 g/ml and 0.9000 g/ml reported by several authors [23,24].…”
Section: Resultssupporting
confidence: 91%
See 1 more Smart Citation
“…The densities of Location 1 and Location 2 with values of 0.8448 g/ml and 0.8227 g/ml fall within the range of 0.78-0.88 g/ml listed for light crude oils while the density of the co-mingled sample from Location 3 with a value of 0.9012 falls with the range (0.88 g/ml-10 g/ml) of crude oils designated as heavy. The density values recorded for these three crude samples agree with 0.8400 g/ml and 0.9000 g/ml reported by several authors [23,24].…”
Section: Resultssupporting
confidence: 91%
“…On the other hand, the crude oil sample from Location 3 with a viscosity value of 115mPa.s which is between 50 mPa.s -50000 mPa.s can be classed as heavy crude. The viscosity range recorded for the three crudes, 5.10 mPa.s -115 mPa.s(Table 4) is in agreement with 50 mPa.s and 112 mPa.s previously reported by several authors[29,24].…”
supporting
confidence: 91%
“…Gas chromatography mass spectrometry (GC-MS) is a hyphenated analytical technique commonly used for environmental analysis due its specific and distinct monitoring capacity, especially when applied in the selective ion mode (Wang and Fingas, 1995;Brassington et al, 2010;Yang et al, 2015). The identification and characterization of petroleum compounds by GC-MS is achieved by comparing retention time and a query mass spectrum with reference mass spectra in a library via spectrum matching.…”
Section: Gas Chromatographymentioning
confidence: 99%
“…The identification and characterization of petroleum compounds by GC-MS is achieved by comparing retention time and a query mass spectrum with reference mass spectra in a library via spectrum matching. Versions of the NIST library, currently containing over 276,000 reference spectra, and search algorithms are available from all major MS manufacturers (Yang et al, 2015). Such method has been used to assess the PAHs in tar-contaminated soils (Lorenzi et al, 2010) and monitor bioremediation of PAHcontaminated soil via in-vessel composting using fresh organic waste (Zhang et al, 2011).…”
Section: Gas Chromatographymentioning
confidence: 99%
See 1 more Smart Citation