Cholesterol oxidase-based determination, by continuous-flow analysis, of total and free cholesterol in serum.

Abstract: We describe a continuous-flow, automated determination of total cholesterol in serum, which is based on enzymatic hydrolysis of cholesterol esters, oxidation of cholesterol by cholesterol oxidase, and colorimetric measurement of liberated perioxide with 4-aminoantipyrine, phenol, and peroxidase. Free cholesterol is determined with the same AutoAnalyzer II manifold and reagents, except that cholesterol esterase is omitted from the reagent. Cholesterol-in-serum materials that have been assayed by an established … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
37
0
1

Year Published

1983
1983
2008
2008

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 143 publications
(39 citation statements)
references
References 0 publications
0
37
0
1
Order By: Relevance
“…Lipids were measured in unfrozen serum and in the high-density lipoprotein (HDL) containing supernatant fraction after precipitation of apolipoprotein B-containing lipoproteins with sodium phosphotungstate and magnesium chloride [19]. Cholesterol and triglyceride were measured enzymatically using automated methods [20,21]. Haemoglobin A 1c (HbA 1c ) was measured by high-performance liquid chromatography (Bio-Rad, Veenendaal, The Netherlands; normal range 4·6-6·1%).…”
Section: Laboratory Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Lipids were measured in unfrozen serum and in the high-density lipoprotein (HDL) containing supernatant fraction after precipitation of apolipoprotein B-containing lipoproteins with sodium phosphotungstate and magnesium chloride [19]. Cholesterol and triglyceride were measured enzymatically using automated methods [20,21]. Haemoglobin A 1c (HbA 1c ) was measured by high-performance liquid chromatography (Bio-Rad, Veenendaal, The Netherlands; normal range 4·6-6·1%).…”
Section: Laboratory Methodsmentioning
confidence: 99%
“…Ten minutes after stopping the infusion, the SA 20 will still be higher than SA 0 , making (SA 20 -SA 10 ) ¼ x 2 × (SA x -SA 0 ), and the AUC during the decline from SA 10 to SA 20…”
Section: Appendixmentioning
confidence: 99%
“…Elles portent sur les protkines totales, le glucose, les triglyctrides, le cholesterol et le calcium. Les methodes de dosage utilisees reposent respectivement sur les travaux de Skeggs et Hochstrasser (1964), Trinder (1969), Fossati et Prencipe (1982), Lie et al (1976) et Gitelman (1967, adaptes aux analyseurs Technicon R.A.…”
Section: Materiel Et Mcthodesunclassified
“…Plasma total cholesterol and triglycerides were measured on a Technicon SMAC by enzymatic methods (Lie et al 1976, Bucolo & David 1973. HDL cholesterol was measured on plasma samples to which EDTA had been added, by enzymatic assay after polyethylene glycol precipitation .…”
Section: Anulytical Methodsmentioning
confidence: 99%