2011
DOI: 10.4028/www.scientific.net/amr.239-242.137
|View full text |Cite
|
Sign up to set email alerts
|

Choice of Electrode Material for Detecting Low Frequency Electric Field in Sea Water

Abstract: Seven types of electrodes have been selected. DC resistances, AC impedances and voltage difference of the electrode pairs have been studied, according to the requirement of low and extra low frequencies electric fields detection in sea water. The feasibilities of these electrodes used for detecting these signals have been studied and explained on theories. The results show that the all-solid-state Ag/AgCl electrode is the most sensitive electrode with its very low DC resistances, AC impedances and the voltage … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 5 publications
0
6
0
Order By: Relevance
“…The sensor electrodes used for the LFEFD in the marine environment have a high demand for having low resistance values at low-frequency signals for high detection sensitivity . Thus, the electrode resistance values at 1 Hz under sine wave excitation signals of 5 or 10 mV are widely used to represent an important parameter of the electrochemical performance of the sensor electrodes. , In this part, we compare the resistance values of the Ag/AgCl electrodes fabricated under conditions of various constant current magnitudes and anodization times and connect them with the surface structure of the electrodes including AgCl deposits.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…The sensor electrodes used for the LFEFD in the marine environment have a high demand for having low resistance values at low-frequency signals for high detection sensitivity . Thus, the electrode resistance values at 1 Hz under sine wave excitation signals of 5 or 10 mV are widely used to represent an important parameter of the electrochemical performance of the sensor electrodes. , In this part, we compare the resistance values of the Ag/AgCl electrodes fabricated under conditions of various constant current magnitudes and anodization times and connect them with the surface structure of the electrodes including AgCl deposits.…”
Section: Resultsmentioning
confidence: 99%
“… 12 As a result of these properties, it has lower resistance and impedance with the stability of electrode voltage, that is, a very small self-noise in seawater, making itself suitable for its use of the marine weak low-frequency electric field detection (LFEFD), compared to other electrodes such as zinc, graphite, and saturated calomel electrodes, and even better than carbon fiber electrodes. 12 …”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations