2012
DOI: 10.1016/j.eswa.2012.04.084
|View full text |Cite
|
Sign up to set email alerts
|

Choice modeling and the brain: A study on the Electroencephalogram (EEG) of preferences

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
42
0
4

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 93 publications
(50 citation statements)
references
References 18 publications
0
42
0
4
Order By: Relevance
“…Para tal efecto, se identificaron tres fabricantes líderes de este tipo de dispositivos a nivel mundial, entre los que se consideraron el Emotiv (Khushaba, et al, 2012), el Neurosky (Poltavski, Biberdorf, & Petros, 2012) y el Neuroelectrics (Neuroelectrics, 2013). Posteriormente se procedió con la selección de uno de estos dispositivos, teniendo en cuenta para ello criterios técnicos tales como: número de canales, acceso a los registros puros de las señales EEG, así como el precio de mercado.…”
Section: Selección De La Icc (Brain Computer Interface)unclassified
“…Para tal efecto, se identificaron tres fabricantes líderes de este tipo de dispositivos a nivel mundial, entre los que se consideraron el Emotiv (Khushaba, et al, 2012), el Neurosky (Poltavski, Biberdorf, & Petros, 2012) y el Neuroelectrics (Neuroelectrics, 2013). Posteriormente se procedió con la selección de uno de estos dispositivos, teniendo en cuenta para ello criterios técnicos tales como: número de canales, acceso a los registros puros de las señales EEG, así como el precio de mercado.…”
Section: Selección De La Icc (Brain Computer Interface)unclassified
“…Meanwhile, the disadvantages of traditional evaluation methods are subject to design uncertainty, simple indicators and can't from multiple perspectives and more scientific for the product evaluation [8]. Due to the need of product design evaluation, and the continuous development of multidisciplinary cross technology.…”
Section: A Evaluation Methods For Product Designmentioning
confidence: 99%
“…The preprocessing of EEG signals started with a detrending removal to eliminate the DC offset in the recorded EEG. This was followed by a linear band pass 13 filter (0.5-45 Hz) that removed the effect of 50 Hz noise and higher frequency artifacts based on the method used by Khushaba et al (2012); Kober et al (2012);and Khushaba et al (2013). Then, the electrooculographic and electromyographic artifacts were detected and deleted using the ADJUST method (Mognon et al, 2011), which is based on the Independent Component Analysis (ICA).…”
Section: Electroencephalogram Processingmentioning
confidence: 99%
“…Prior to use, all of the felt pads on top of the sensor must be moistened with a saline solution (Khushaba et al 2012). The Emotiv device was selected because of its low cost and portability so that the study could be performed in the school setting.…”
Section:  Physiological Instrument Epoc-based Eeg Data Collection (Ementioning
confidence: 99%