2001
DOI: 10.1002/1522-2683(200109)22:15<3291::aid-elps3291>3.0.co;2-a
|View full text |Cite
|
Sign up to set email alerts
|

Chiral separation of amino acid esters by micellar electrokinetic chromatography

Abstract: Micellar electrokinetic chromatography (MEKC) was used for the chiral separation of uncharged analytes (C- and N-protected amino acids). Sodium dodecyl sulfate (SDS) was the micelle forming agent, and different cyclodextrin (CD) derivatives were added as chiral selectors. Suitable conditions for the enantioseparation were found by variation of the separation conditions. The influence of addition of organic solvents like acetonitrile or methanol, and other chiral additives (camphor-10-sulfonic acid, malic acid)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2002
2002
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…Salami et al. used (+)‐18‐crown‐6‐tetracarbonic acid for resolving dipeptides. The addition of acetonitrile and tetra‐ n ‐butylammonium bromide resulted in improved chiral separation.…”
Section: Chiral Separation Of Small Peptidesmentioning
confidence: 99%
“…Salami et al. used (+)‐18‐crown‐6‐tetracarbonic acid for resolving dipeptides. The addition of acetonitrile and tetra‐ n ‐butylammonium bromide resulted in improved chiral separation.…”
Section: Chiral Separation Of Small Peptidesmentioning
confidence: 99%
“…The mechanism of recognition is hydrogen bonding between oxygens on the planar chiral agent and the hydrogens of the amine group of the analyte [148]. The planar geometry of the selectand allows the formation of two diastereomeric complexes based on interactions with the faces of the crown ether that have different binding constants [149]. The structure of the main chiral crown ether employed in chiral EKC analyses, (1)-(18-crown-6)-2,3,11,12-tetracarboxylic acid (18C 6 H 4 ), is shown in Fig.…”
Section: Crown Ethersmentioning
confidence: 99%
“…8. Amino acids and some amino acid derivatives were enantioseparated by Salami et al [149] using 18C 6 H 4 . They found that larger groups at the analyte chiral center allowed for chiral discrimination (i.e., benzyl), whereas smaller functionalities precluded resolution (i.e., methyl).…”
Section: Crown Ethersmentioning
confidence: 99%
“…In CD-MEKC, a neutral or basic buffer (pH 7-10) containing both sodium dodecyl sulfate (SDS) and ␤-CD is mainly used as the BGS [63][64][65][66][67][68][69][70][71][72][73][74][75][76]. Modified CDs such as HP-␤-CD [76][77][78], DM-␤-CD [78] and HP-␥-CD [79] have been also utilized in the CD-MEKC mode. Because the incorporation by the SDS micelle compete with the inclusion into the cavity of CDs, the CD-MEKC separation of racemic amino acids can be easily optimized by tuning the concentrations of SDS and CDs.…”
Section: Cd-mekcmentioning
confidence: 99%