Chiral electrokinetic chromatography‐electrospray ionization‐mass spectrometry using a double junction interface

Abstract: A double junction interface was utilized to preserve separation efficiency and alleviate ion suppression from sulfated β-cyclodextrin (S-β-CD) in electrokinetic chromatography-electrospray ionization-mass spectrometry. The utility of the approach was demonstrated by chiral EKC-MS analysis of dihydroxyphenylalanine and methyldihydroxyphenylalanine enantiomers using either low concentration (counter-migration mode; 0.1% S-β-CD) or high concentration (carrier mode; 2% S-β-CD). In the counter-migration mode, S-β-C… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 26 publications
0
11
0
Order By: Relevance
“…With this approach, the authors obtained good results, avoiding contamination of the MS due to the absence of the charged CD in the interface also increasing the sensitivity. The CD was migrating in the counter‐flow mode . On the other hand, a similar approach was advanced by Fanali's and Chankvetadze's groups in 1998 for the separation of ibuprofen and some of its metabolites using CE‐MS with a commercial ESI interface and adding to the BGE vancomycin.…”
Section: Selected Applications Related To Chiral Separationmentioning
confidence: 99%
“…With this approach, the authors obtained good results, avoiding contamination of the MS due to the absence of the charged CD in the interface also increasing the sensitivity. The CD was migrating in the counter‐flow mode . On the other hand, a similar approach was advanced by Fanali's and Chankvetadze's groups in 1998 for the separation of ibuprofen and some of its metabolites using CE‐MS with a commercial ESI interface and adding to the BGE vancomycin.…”
Section: Selected Applications Related To Chiral Separationmentioning
confidence: 99%
“…dl ‐2‐amino‐2‐methyl‐3‐(3,4‐dihydroxyphenyl) propanoic acid (MDOPA) and dl ‐2‐amino‐3‐(3,4‐dihydroxyphenyl) propanoic acid (DOPA) enantiomers were separated and identified using electrokinetic chromatography ESI + MS . A double junction interface preserved separation efficiency and alleviated ion suppression from sulfated β‐CD (S‐β‐CD).…”
Section: Ce/developments In Detectionmentioning
confidence: 99%
“…Regarding MS detection, noteworthy that it has been the most employed alternative detection technique in the last two years, which demonstrates the high potential of the coupling CE‐MS for chiral separations. As it can be seen in Table , the methodologies developed have been realized by different CE modes, such as EKC , MEKC , CEC , and ligand exchange CE (LECE) , which have been coupled for the analytes detection to different mass analyzers as quadrupole, IT, triple quadrupole, and QTOF. Using EKC mode with CDs, additional strategies, such as PFT or CMT , have been employed in order to overcome the possibility of contamination of the ionization source induced by the chiral selector and to increase method sensitivity.…”
Section: Approaches To Improve the Detection Sensitivitymentioning
confidence: 99%
“…As it can be seen in Table , the methodologies developed have been realized by different CE modes, such as EKC , MEKC , CEC , and ligand exchange CE (LECE) , which have been coupled for the analytes detection to different mass analyzers as quadrupole, IT, triple quadrupole, and QTOF. Using EKC mode with CDs, additional strategies, such as PFT or CMT , have been employed in order to overcome the possibility of contamination of the ionization source induced by the chiral selector and to increase method sensitivity. PFT strategy has been carried out with a neutral CD (α‐CD) in combination with an ionic capillary coating (polybrene–dextran sulfate–polybrene) that reversed the EOF , and in combination with CMT when a negative CD (S‐β‐CD) was used in normal polarity (anionic CD migrated in counter current from the MS detector during the separation) .…”
Section: Approaches To Improve the Detection Sensitivitymentioning
confidence: 99%
See 1 more Smart Citation