2004
DOI: 10.1002/elps.200305796
|View full text |Cite
|
Sign up to set email alerts
|

Chiral capillary electrophoretic resolution of baclofen, gabaergic ligand, using highly sulfated cyclodextrins

Abstract: Using cyclodextrin-capillary zone electrophoresis (CD-CZE), baseline separation of baclofen, a potent GABA(B) agonist; was achieved. A method for the enantioresolution of this gamma-aminobutyric acid (GABA) and determination of enantiomeric purity was developed using CDs (highly sulfated-CD or highly S-CD) as chiral selectors and capillaries dynamically coated with polyethylene oxide (PEO). Operational parameters, such as the nature and concentration of the chiral selectors, buffer concentration, organic modif… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
17
0

Year Published

2005
2005
2006
2006

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 17 publications
(18 citation statements)
references
References 42 publications
1
17
0
Order By: Relevance
“…The influence of the highly S-CD concentration (0.5 to 5%) on the separation is shown in Table 3. Chiral recognition was achieved for all concentrations tested with highly S-b-CD (compounds 1 [6] and 4) and highly S-a-CD (compounds 2 and 3) but only with high concentrations with highly S-b-CD for 3. Migration times (t) decrease sharply when the concentration of highly S-CD is increased from 0.5 to 2% (decrease of about 100%) and slowly from 2 to 5%.…”
Section: Effect Of the Highly S-cd Concentration On The Separationmentioning
confidence: 99%
See 2 more Smart Citations
“…The influence of the highly S-CD concentration (0.5 to 5%) on the separation is shown in Table 3. Chiral recognition was achieved for all concentrations tested with highly S-b-CD (compounds 1 [6] and 4) and highly S-a-CD (compounds 2 and 3) but only with high concentrations with highly S-b-CD for 3. Migration times (t) decrease sharply when the concentration of highly S-CD is increased from 0.5 to 2% (decrease of about 100%) and slowly from 2 to 5%.…”
Section: Effect Of the Highly S-cd Concentration On The Separationmentioning
confidence: 99%
“…They were discovered to be potent antagonists and are currently used as biological HPLC is one of the most appropriate techniques both in preparative (by furnishing both enantiomers) and analytical modes. In a recent paper [6], we cited in the references all the chromatographic separations of baclofen. We also described the analytical and/or preparative enantiospecific chromatographic separation of the antagonists 2, 3, 4 [7,8] with a chiral crown ether moiety (CR1) as chiral selector.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The same group investigated the chiral resolution of baclofen, using approximately the same methodology. Good enantiomeric separation was obtained using highly S-b-CD and a capillary dynamically coated with polyethylene oxide [152]. Zhou et al [153] investigated the chiral separation of a substituted imidazole p38 MAP kinase inhibitor and two intermediates with various sulfated-CDs.…”
Section: Enantiomeric Purity Testingmentioning
confidence: 98%
“…For chiral analysis, different methods were developed such as GC with electron capture detection [26,27] as well as HPLC coupled with fluorescence [28,29], UV [30,31], and MS detection [32]. As reported in the literature, there are only few papers dedicated to the chiral separation of baclofen by CE with derivatized CDs [33] and crown ethers [34,35] in acidic media with UV detection. However, to our knowledge, there is only one study presenting LIF detection [36] and a-CD as chiral selector.…”
Section: Introductionmentioning
confidence: 99%