2014
DOI: 10.14346/jkosos.2014.29.6.125
|View full text |Cite
|
Sign up to set email alerts
|

Chest Compression Energy(kg) Measurement of 4 Types of Rescue Device on the Floor

Abstract: :The purpose of this study is to investigate the effect of high quality CPR using the 4 types of rescue device equipment and chest compressions energy measurement in pre-hospital settings. So, we used the mode to insert load cell in ALS Skill master Manikin to develop CFMM(Compression Force Measurement Manikin) on main stretcher, CPR board, long spine board, scoop stretcher and floor. And, our research team could know that the main stretcher needed average force of 32.55 (±1.01) kg, CPR board of 27.23 (±1.08) … Show more