2020
DOI: 10.1007/s11356-020-10881-2
|View full text |Cite
|
Sign up to set email alerts
|

Chemometric tools applied to optimize a fast solid-phase microextraction method for analysis of polycyclic aromatic hydrocarbons in produced water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 45 publications
0
4
0
Order By: Relevance
“…However, even in this modified domain, PAHs with MM above 252 Da (indeno[1,2,3-c,d]pyrene (IcdPY), dibenzo[a,h]anthracene (DahA) and benzo[g,h,i]perylene (BghiPE)) were not detected in all the experiments, thus generating poor models. The positive effect of higher T EXP for the sorption of H-PAHs onto PDMS fibers has been already reported [ 21 , 35 ] and is probably due to their lower vapor pressure, requiring higher temperature to pass to the vapor phase. On the other hand, too-high temperatures generally favor the analytes’ desorption, since the sorption onto the fiber is an exothermic process [ 40 ].…”
Section: Resultsmentioning
confidence: 74%
See 3 more Smart Citations
“…However, even in this modified domain, PAHs with MM above 252 Da (indeno[1,2,3-c,d]pyrene (IcdPY), dibenzo[a,h]anthracene (DahA) and benzo[g,h,i]perylene (BghiPE)) were not detected in all the experiments, thus generating poor models. The positive effect of higher T EXP for the sorption of H-PAHs onto PDMS fibers has been already reported [ 21 , 35 ] and is probably due to their lower vapor pressure, requiring higher temperature to pass to the vapor phase. On the other hand, too-high temperatures generally favor the analytes’ desorption, since the sorption onto the fiber is an exothermic process [ 40 ].…”
Section: Resultsmentioning
confidence: 74%
“…As mentioned, during the first set of experiments, the H-PAHs (specifically BaA, CHR, BbF, BkF, and BaPY) were detected in only two experiments. In these trials, both T EXP and t EXP were at the highest level, thus suggesting the further investigation of only these two variables by modifying the domain toward higher values [ 21 ]. Therefore, as indicated in Section 3.3 , the range investigated for T EXP was moved from 40–70 °C to 80–100 °C, while t EXP was explored in the range of 60–90 min (prior range 20–50 min).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations