2005
DOI: 10.1016/j.bios.2004.12.023
|View full text |Cite
|
Sign up to set email alerts
|

Chemometric exploration of an amperometric biosensor array for fast determination of wastewater quality

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
55
1
2

Year Published

2006
2006
2020
2020

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 75 publications
(58 citation statements)
references
References 22 publications
0
55
1
2
Order By: Relevance
“…In the short term specific bioelectrochemical sensors will become more widespread and perform electrochemical bioassays for example to detect water born pathogens (Fritsch et al, 2008) and toxic algae (Diercks et al, 2008a), water quality assessment (Tonning et al, 2005) and general environmental monitoring (Marrazza et al, 1999). In the medium term, arrays of bioelectrochemical sensors could have applications in biochemical finger printing.…”
Section: Future Trendsmentioning
confidence: 99%
“…In the short term specific bioelectrochemical sensors will become more widespread and perform electrochemical bioassays for example to detect water born pathogens (Fritsch et al, 2008) and toxic algae (Diercks et al, 2008a), water quality assessment (Tonning et al, 2005) and general environmental monitoring (Marrazza et al, 1999). In the medium term, arrays of bioelectrochemical sensors could have applications in biochemical finger printing.…”
Section: Future Trendsmentioning
confidence: 99%
“…75 A tirosinase pode ser inibida por uma gama de poluentes, tais como carbamatos, organofosforados, ditiocarbamatos, atrazinas, tiuréas, ácidos carboxílicos aromáticos, triazinas, herbicidas, clorofenóis e agentes quelantes de cobre. [75][76][77][78][79][80][81][82][83][84][85][86] Desta forma, biossensores baseados em enzimas tirosinases podem ser empregados com biossensores baseados em inibição enzimática, detectando tanto o decrescimento da quantidade de oxigênio no meio reacional, quanto a formação da quinona, em presença do agente inibidor. Eletrodos de carbono, ouro, ouro modificado e eletrodos de Clark têm sido empregados na construção destes sensores.…”
Section: Biossensores Baseados Em Enzimas Tirosinasesunclassified
“…Although reports of SBP-based 163 biosensors are emerging, HRP biosensor research dominates and has continued to 164 develop through many forms, from the traditional voltammetric-and amperometric-165 based methods of detection, to nano-sized devices. Real time quantification of 166 hydrogen peroxide continues to be one of the main reasons for sensor development 167 [44], although other diverse applications include the detection of glucose [45], ethanol 168 [46] and tumour markers in vivo [47]. Enzyme-based biosensors require rapid and 169 uniform transfer of electrons generated at the enzyme active site to the transducer.…”
Section: Device That Brings Together An Immobilised Biological Sensinmentioning
confidence: 99%