2012
DOI: 10.1007/s13361-012-0471-2
|View full text |Cite
|
Sign up to set email alerts
|

Chemometric Data Analysis for Deconvolution of Overlapped Ion Mobility Profiles

Abstract: We present the details of a data analysis approach for deconvolution of the ion mobility (IM) overlapped or unresolved species. This approach takes advantage of the ion fragmentation variations as a function of the IM arrival time. The data analysis involves the use of an in-house developed data preprocessing platform for the conversion of the original post-IM/collisioninduced dissociation mass spectrometry (post-IM/CID MS) data to a Matlab compatible format for chemometric analysis. We show that principle com… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
36
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 29 publications
(36 citation statements)
references
References 26 publications
0
36
0
Order By: Relevance
“…We also used a previously reported post-IM/CID-chemometric approach to examine the presence of potential IM overlapped conformers [59]. Results from post-IM/CID-chemometric studies further confirmed the absence of resolvable multiple IM overlapped conformers for any of the protonated Z-PG and [Z-PG + alkali metal] + species.…”
Section: Im-ms Of [Z-pg + H] + and [Z-pg + Alkali Metal] +mentioning
confidence: 65%
“…We also used a previously reported post-IM/CID-chemometric approach to examine the presence of potential IM overlapped conformers [59]. Results from post-IM/CID-chemometric studies further confirmed the absence of resolvable multiple IM overlapped conformers for any of the protonated Z-PG and [Z-PG + alkali metal] + species.…”
Section: Im-ms Of [Z-pg + H] + and [Z-pg + Alkali Metal] +mentioning
confidence: 65%
“…TWIM-MS experiments were performed as previously described 37,39,4244,46 using Synapt G1 (for the pentapeptide binary mixture) and G2-S (for the hexapeptide quaternary mixture) systems (Waters Corporation, Milford, MA, USA). Experimental details on collection of TWIM-MS data reported in this manuscript are included in the supporting information, Table S1.…”
Section: Methodsmentioning
confidence: 99%
“…Previously, we introduced a chemometric data deconvolution technique 37 based on SIMPLe-to-use Interactive Self-modeling Mixture Analysis (SIMPLISMA) 38 which allowed the extraction of “pure” IM and post-IM/CID mass spectra for IM-unresolved species. Subsequently, we integrated SIMPLISMA into an automated IM deconvolution (AIMD) software, which improved the speed and accuracy of IM-MS analyses.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…[30][31][32][33][34] Although these valuable developments have generated impressive results, it may be challenging to implement them in shared instruments, such as in core facilities, or for the everyday user. 8,29,[31][32][33][34][35][36][37] Hence, it is desirable to complement instrument development efforts by designing improved methods for IM-MS data acquisition and interpretation that are independent of the IMS and/or IM-MS instrumental hardware. 8,29,[31][32][33][34][35][36][37] Hence, it is desirable to complement instrument development efforts by designing improved methods for IM-MS data acquisition and interpretation that are independent of the IMS and/or IM-MS instrumental hardware.…”
Section: Introductionmentioning
confidence: 99%