2012
DOI: 10.1007/s10544-012-9716-x
|View full text |Cite
|
Sign up to set email alerts
|

Chemiluminescence microfluidic system of gold nanoparticles enhanced luminol-silver nitrate for the determination of vitamin B12

Abstract: A rapid and sensitive chemiluminescence (CL) system coupled with a microfluidic chip has been presented to determine vitamin B12 (VB12) based on the reaction of luminol and silver nitrate (AgNO(3)) in the presence of gold nanoparticles (AuNPs). A microfluidic chip was fabricated by a soft-lithographic procedure using polydimethyl siloxane (PDMS) having four inlets and one outlet with a 200 μm wide, 250 μm deep, and 100 mm long microchannel. Ag(+) was used as a chemiluminogenic oxidant in this CL reaction which… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 30 publications
(14 citation statements)
references
References 43 publications
0
14
0
Order By: Relevance
“…Luminol reacts with silver nitrate by using gold nanoparticles as a catalyst to produce luminol radicals, which react with dissolved oxygen and emit CL light. This CL method was used to determine the amount of vitamin B 12 in tablets and multivitamin preparations [174]. …”
Section: Pharmaceutical Analysismentioning
confidence: 99%
“…Luminol reacts with silver nitrate by using gold nanoparticles as a catalyst to produce luminol radicals, which react with dissolved oxygen and emit CL light. This CL method was used to determine the amount of vitamin B 12 in tablets and multivitamin preparations [174]. …”
Section: Pharmaceutical Analysismentioning
confidence: 99%
“…S2, AgNO 3 was reduced to Ag atoms and luminol was oxidized to luminol radical which were catalyzed by gold nanoparticles and happened on the surface of gold nanoparticles. Luminol radical was then followed by reaction with the dissolved oxygen, giving rise to light emission12394041. The possible mechanism of the enhanced luminol–H 2 O 2 CL reaction induced by CdTe QDs was shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…120 Recently, microfluidic chemiluminescence systems for measurements of vitamin B1 and B12 levels in tablets or eggs have also been reported, with very high sensitivity compared to reported methods. 121123 Besides system miniaturization, another distinct merit of microfluidics technology is the ease of parallelization, which can be realized simply by introducing multiple channels. This can increase throughput or enable multiplexed analysis.…”
Section: Microfluidic Monitoring Of Nutrient Contentmentioning
confidence: 99%