2002
DOI: 10.1007/s006040200003
|View full text |Cite
|
Sign up to set email alerts
|

Chemically Treated Silver Electrodes for the Determination of Cysteine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0
3

Year Published

2003
2003
2015
2015

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 24 publications
(20 citation statements)
references
References 0 publications
0
17
0
3
Order By: Relevance
“…1 The European Pharmacopeia recommended iodimetric titration for pharmaceutical formulations analysis. 2 Other reported methods described in the literature comprise: titrimetry, 3,4 spectrophotometry, [5][6][7][8][9] fluorimetry, [10][11][12] chromatography, 13,14 potentiometry, 15 conductometry 16 and voltametry [17][18][19] for the determination of NAC in pure form, in dosage forms and in biological samples.…”
Section: Introductionmentioning
confidence: 99%
“…1 The European Pharmacopeia recommended iodimetric titration for pharmaceutical formulations analysis. 2 Other reported methods described in the literature comprise: titrimetry, 3,4 spectrophotometry, [5][6][7][8][9] fluorimetry, [10][11][12] chromatography, 13,14 potentiometry, 15 conductometry 16 and voltametry [17][18][19] for the determination of NAC in pure form, in dosage forms and in biological samples.…”
Section: Introductionmentioning
confidence: 99%
“…The flowinjection analysis (FIA) became a versatile instrumental tool that contributed substantially to the development of automation in pharmaceutical analysis due to its simplicity, low cost and relatively short analysis time. 14 There are several published flow-injection methods for the determination of NAC with potentiometric 15,16 and spectrophotometric detector. [17][18][19][20][21][22][23] Described flow-injection spectrometric methods have adequate sample analysis frequency but, on the other hand, narrow analytical range and lack of sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…O sistema de análise por injeção em fluxo proposto é simples e permite a determinação de N-acetil-L-cisteína em formulações farmacêuticas com alta freqüência analítica, quando comparado com os procedimentos em fluxo descritos na literatura 15,16 . A determinação foi realizada em produtos farmacêuticos disponibilizados na forma granulada, pois em produtos efervescentes e xaropes contendo ácido cítrico, em concentração superior àquela tolerada (Tabela 1), a interferência desse excipiente foi um fator limitante.…”
Section: Conclusõesunclassified
“…Um sistema de análise por injeção em fluxo para determinação indireta de N-acetil-L-cisteína baseado na detecção potenciométrica do íon iodeto produzido na reação de oxidação do analito por um fluxo de solução de iodo (I 2 ) foi proposto, utilizando um eletrodo de prata modificado para detecção do íon iodeto 16 . Solução de Cério(IV) como reagente oxidante forte tem sido empregada na determinação de produtos farmacêuticos em análise por injeção em fluxo com detecção biamperométrica 17 e quimiluminescentes 18,19 .…”
Section: Introductionunclassified