1977
DOI: 10.1021/ac50022a049
|View full text |Cite
|
Sign up to set email alerts
|

Chemically-bonded aminosilane stationary phase for the high-performance liquid chromatographic separation of polynuclear aromatic compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
85
0

Year Published

1980
1980
2013
2013

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 251 publications
(89 citation statements)
references
References 19 publications
3
85
0
Order By: Relevance
“…Conventional fluorescence detectors, of the scanning type, have also aided in the identification of Chromatographie peaks [10] b> the stopped-flow scanning technique.…”
Section: Introductionmentioning
confidence: 99%
“…Conventional fluorescence detectors, of the scanning type, have also aided in the identification of Chromatographie peaks [10] b> the stopped-flow scanning technique.…”
Section: Introductionmentioning
confidence: 99%
“…The baseline resolved result at the bottom right of Figure 5 (94 ± 1% fossil), is a very recent datum that was achieved by the offline GC/AMS technique where the influence of the baseline was essentially eliminated through the special pre-purification technique of PAH ring size fractionation (Wise et al 1977;Pearson et al 1997). Two very important conclusions derive from this work.…”
Section: Speciation; and A Special Atmospheric Reference Materialsmentioning
confidence: 79%
“…A principal observation is that the initial 14 C result for benzo(ghi)perylene has a large uncertainty, due to the large "unresolved complex mixture" (ucm) of unknown isotopic composition that coeluted and was recovered in trap-6, the B(ghi)P trap. The vastly improved result showing 94 ± 1% fossil carbon was achieved through an improved purification technique involving the isolation of PAH ring size fractions (Wise et al 1977;Currie et al 1999a). ada and the singular enhancement of biomass burning aerosol carbon at Summit, Greenland on 5 August 1994.…”
Section: A Multidisciplinary Case Study; Implications For Future Resementioning
confidence: 99%
“…A third method of chemical fractionation now being evaluated utilizes high performance liquid chromatography and is based on the method described by Wise et al (1977). With this technique, the undiluted sample or the sample in a hexane or hexane:methylene chloride solvent is loaded onto a normalphase NH2 column.…”
Section: • Solvent Refined Coal Effluent/product Characterizationmentioning
confidence: 99%