Chemical reactions induced in polymers by keV ions, electrons and photons

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
40
0

Year Published

1998
1998
2012
2012

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 85 publications
(40 citation statements)
references
References 12 publications
0
40
0
Order By: Relevance
“…Spectra were taken while maintaining a primary ion dose of 3.3 ð 10 12 ions/cm 2 to ensure static SIMS conditions. 3 Mass resolution (m/m) at the C 4 H 8 N C peak was always greater than 6000. Spectra were collected from three spots on each sample.…”
Section: Tof-simsmentioning
confidence: 99%
“…Spectra were taken while maintaining a primary ion dose of 3.3 ð 10 12 ions/cm 2 to ensure static SIMS conditions. 3 Mass resolution (m/m) at the C 4 H 8 N C peak was always greater than 6000. Spectra were collected from three spots on each sample.…”
Section: Tof-simsmentioning
confidence: 99%
“…The area of analysis for each spectrum was 100 m ϫ 10 m. The total ion dose used to acquire each spectrum was less than 2 ϫ 10 12 ions/cm 2 to ensure static conditions. 12 The mass resolution (m/⌬m) of the secondary ion peaks was typically between 6000 and 9500. At least three replicates were prepared for each sample, with three spectra acquired from each replicate.…”
Section: Tof-simsmentioning
confidence: 99%
“…3(a) includes four parts, TP (69, 70), GM (104, 105), CK (115, 116) and GC (126, 127), out of the six underlined parts in the above sequence. In addition, one of the other two parts MK (11,12) is very close to this site, and the other LC(75, 76) can also be at this site, because it is in the form of a random coil which does not maintain a stable structure. The ribbon diagram of the lysozyme is shown in Fig.…”
Section: Kvf[grc]elaa Amkrhgldny Rgyslgnwvc Aakfesnfnt Qatnrntdgs Tdymentioning
confidence: 94%
“…Positive ion spectra which were obtained with TOF-SIMS to TRIFT-IV (Physical Electronics, Eden Prairie, MN, USA) using 12 keV Ga + and 17 keV C 60 + primary ion sources, were acquired at up to 1000 m/z while maintaining the primary ion dose at less than 10 12 ions/cm 2 to ensure static conditions [11] All the spectra were calibrated to the CH 3 + , C 2 H 5 + , C 3 H 5 + and C 4 H 7 + peaks before data analysis.…”
Section: Tof-sims Measurementmentioning
confidence: 99%