1994
DOI: 10.1016/s0032-3861(05)80013-8
|View full text |Cite
|
Sign up to set email alerts
|

Chemical modification of poly(ether ether ketone) for size exclusion chromatography at room temperature: 1. Absolute molecular-mass determination for sulfonated PEEK

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
17
0
5

Year Published

1996
1996
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(24 citation statements)
references
References 14 publications
2
17
0
5
Order By: Relevance
“…The accuracy of this type of measurement is arguable because the viscosity measurements were performed by dissolving the polymer powder in H 2 SO 4 95% v/v, which is very hygroscopic and any water uptake could increase the viscosity of H 2 SO 4 resulting in a considerable error for MW determination. Regardless of this source of variation, the values obtained for the polymer grades were within the range reported in the literature [34,35]. However, when looking at the viscosity of the dope solutions (Table 2) one can observe that the performance of the different membranes followed a trend: the higher the viscosity the tighter the membrane.…”
Section: Performance In Thfsupporting
confidence: 80%
“…The accuracy of this type of measurement is arguable because the viscosity measurements were performed by dissolving the polymer powder in H 2 SO 4 95% v/v, which is very hygroscopic and any water uptake could increase the viscosity of H 2 SO 4 resulting in a considerable error for MW determination. Regardless of this source of variation, the values obtained for the polymer grades were within the range reported in the literature [34,35]. However, when looking at the viscosity of the dope solutions (Table 2) one can observe that the performance of the different membranes followed a trend: the higher the viscosity the tighter the membrane.…”
Section: Performance In Thfsupporting
confidence: 80%
“…Сульфирование проводили по методике [3]. Образцы растворяли в серной кислоте с плотностью не ниже 1,8355 г/см 3 и выдерживали при температуре 40°С 12 дня.…”
Section: материалы и методы исследованияunclassified
“…Альтернативным подходом представляется получение растворимых производных ПЭЭК. Например, сульфирование ПЭЭК обеспечивает получение производных этого полимера, растворимых в N-метилпирролидоне (N-МП), диметилсульфоксиде, диметилформамиде при комнатной температуре [3]…”
Section: Introductionunclassified
“…For example, PEEK may be sulfonated at the hydroquinone residue simply by dissolving it at ambient temperature in concentrated (96-98%) sulfuric acid, and the resulting, amorphous, polysulfonate ionomer is soluble in dipolar aprotic solvents. 8,9 Lithium salts of sulfonated PEEK can then be analyzed by roomtemperature GPC in N-methylpyrrolidone. 10 Diphenyl sulfone, 2,2-diphenylethylamine and 3,3-diphenylpropylamine were purchased from Acros and were used without further purification.…”
Section: But This Technique Requires a Combination Of High Column Temmentioning
confidence: 99%