1975
DOI: 10.1021/ac60351a031
|View full text |Cite
|
Sign up to set email alerts
|

Chemical ionization mass spectrometric determination of organic compounds in solution at the part per million level

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
7
0

Year Published

1976
1976
1978
1978

Publication Types

Select...
5
3

Relationship

4
4

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 9 publications
0
7
0
Order By: Relevance
“…There are also considerable data available on the temperature dependence of ester Cl spectra (7), and the mechanisms of the formation of the major fragment ions have been elucidated (8) through deuterium labeling studies. Furthermore, since most esters are at least sparingly soluble in water, they may be introduced very conveniently into the Cl mass spectrometer as dilute aqueous solutions (9,10), thereby allowing precise control of the pressures of both the ester and the water reagent gas. All of these considerations, plus their widespread occurrence both in nature and in widely used chemical processes and products, led us to choose esters for this initial study of the potential analytical applications and utility of the new drift tube chemical ionization source.…”
mentioning
confidence: 99%
“…There are also considerable data available on the temperature dependence of ester Cl spectra (7), and the mechanisms of the formation of the major fragment ions have been elucidated (8) through deuterium labeling studies. Furthermore, since most esters are at least sparingly soluble in water, they may be introduced very conveniently into the Cl mass spectrometer as dilute aqueous solutions (9,10), thereby allowing precise control of the pressures of both the ester and the water reagent gas. All of these considerations, plus their widespread occurrence both in nature and in widely used chemical processes and products, led us to choose esters for this initial study of the potential analytical applications and utility of the new drift tube chemical ionization source.…”
mentioning
confidence: 99%
“…The modifications to our Du Pont 21-490B mass spectrometer for conventional chemical ionization work have been described in previous publications. 3,5,7 The new pulsed high-pressure source is shown in Figure 1. All parts are stainless steel except for the insulator ring, which is made of Macor machinable glass ceramic.10 The shapes of the source block and source mounting plate are such that the insulator ring is shielded from the ions, electrons, and reactive species generated within the ion source.…”
Section: Methodsmentioning
confidence: 99%
“…The equilibrium constant for reaction 8 is readily calculated from the ratio of +•( 2 ) to MH+ and the measured pressure of water in the source. It is also possible to calculate a value of the equilibrium constant for the (3,4) vides an internal check on the quality of the data. Figure 6 compares our results for the various equilibria in water with those from Kebarle's laboratory (solid lines).14 •15 The quite good agreement between the two sets of data indicates that thermochemical equilibrium is.…”
Section: Methodsmentioning
confidence: 99%
“…It is readily available in a highly pure form, easy to handle, and inexpensive. Furthermore, dilute aqueous solutions of organic compounds can be directly injected into a Cl mass spectrometer with no prior sample preparation (6).…”
mentioning
confidence: 99%
“…We observe that difunctional compounds tend to accentuate the formation of MH+(H20)" clusters. In a previous publication (6), it was noted that variations in cluster ion peak intensities might yield structural and conformational information. An important property of difunctional compounds is the distance between functional groups.…”
mentioning
confidence: 99%