2004
DOI: 10.1021/es049832d
|View full text |Cite
|
Sign up to set email alerts
|

Chemical Fingerprinting of Petroleum Biomarkers Using Time Warping and PCA

Abstract: A new method for chemical fingerprinting of petroleum biomakers is described. The method consists of GC-MS analysis, preprocessing of GC-MS chromatograms, and principal component analysis (PCA) of selected regions. The preprocessing consists of baseline removal by derivatization, normalization, and alignment using correlation optimized warping. The method was applied to chromatograms of m/z 217 (tricyclic and tetracyclic steranes) of oil spill samples and source oils. Oil spill samples collected from the coast… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0
1

Year Published

2006
2006
2018
2018

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 96 publications
(37 citation statements)
references
References 25 publications
0
35
0
1
Order By: Relevance
“…GCImage (Zoex, Houston, USA) software was used for identification and to generate the figures. The data set were folded and aligned by using correlation optimized warping (COW), 19,20 and MPCA was performed using PLS Toolbox 4.0 (Eigenvector Technologies, Manson, EUA) running on MatLab 7.8 environment (MathWorks, Natick-MA, USA).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…GCImage (Zoex, Houston, USA) software was used for identification and to generate the figures. The data set were folded and aligned by using correlation optimized warping (COW), 19,20 and MPCA was performed using PLS Toolbox 4.0 (Eigenvector Technologies, Manson, EUA) running on MatLab 7.8 environment (MathWorks, Natick-MA, USA).…”
Section: Resultsmentioning
confidence: 99%
“…19,20 MPCA was used with comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometer (GC×GC-TOF-MS) in order to identify the differences in chemical composition between three different species of plants and two types of extracts, providing a direct relation between the different metabolite concentrations. 21 Ventura et al 17 used MPCA on large numbers of specific chemical components resolved with GC×GC-FID to determine the molecular relation of eight different maltene fractions of crude oils and performed a classification between the samples.…”
Section: Introductionmentioning
confidence: 99%
“…Christensen y colaboradores [15] utilizaron el método de análisis de componentes principales (PCA) para detectar grupos de crudos similares a partir de datos cromatográficos pre-procesados. Los fragmentogramas de masas para el ion en m/z 217 (que selecciona las señales de esteranos tri-y tetracíclicos), fueron los datos originales y su procesamiento previo consistió en alinear los cromatogramas para corregir los desplazamientos de los tiempos de retención, causados por diferencias instrumentales.…”
Section: µL) Gc-ms/ms (Qqq) Modo De Adquisición: Barrido Completo (unclassified
“…reference chromatogram) is often made from a priori knowledge on the data set. This could, for example, be the chromatogram in the middle of the run sequence [2,10] or the chromatogram containing the highest number of common chemical constituents (i.e. peaks) [3][4].…”
Section: Reference Chromatogram Selectionmentioning
confidence: 99%