2021
DOI: 10.1080/0972060x.2021.1921622
|View full text |Cite
|
Sign up to set email alerts
|

Chemical Composition and Antioxidant Activity of Root Essential Oil of Different Salvia leriifolia Populations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
0
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 41 publications
0
0
0
Order By: Relevance
“…The gas chromatographic conditions were set as follows: Interface temperature: 280 °C; Injector temperature: 260 °C; Carrier gas: He; Flow rate: 1.0 mL/min; Heating program setting: initial temperature of 50 °C for 4 min, 6 °C/min to 280 °C, and held for 3 min. The mass spectrum conditions were as follows: EI: 70 eV; Scanning range: 25–500 amu; Scan rate: 4.0 scan/s; Quadrupole temperature: 150 °C; Sample size: 0.3 µL [ 77 ]. GC-FID analysis was performed using a PerkinElmer gas chromatograph (Clarus 500, Shelton, CT, USA) with an HP-5 fused silica capillary column (30 m × 0.25 mm, film thickness of 0.25 μm, Agilent, Santa Clara, CA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The gas chromatographic conditions were set as follows: Interface temperature: 280 °C; Injector temperature: 260 °C; Carrier gas: He; Flow rate: 1.0 mL/min; Heating program setting: initial temperature of 50 °C for 4 min, 6 °C/min to 280 °C, and held for 3 min. The mass spectrum conditions were as follows: EI: 70 eV; Scanning range: 25–500 amu; Scan rate: 4.0 scan/s; Quadrupole temperature: 150 °C; Sample size: 0.3 µL [ 77 ]. GC-FID analysis was performed using a PerkinElmer gas chromatograph (Clarus 500, Shelton, CT, USA) with an HP-5 fused silica capillary column (30 m × 0.25 mm, film thickness of 0.25 μm, Agilent, Santa Clara, CA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…Helium was used as the carrier gas at a 1.1 mL/min velocity. The mass spectrometer conditions were as follows: electron impact (EI) mode (electron energy = 70 eV), a scan range of 25-500 amu, a scan rate of 4.0 scans/s, and a quadrupole temperature of 150 • C. A 1% w/v sample solution in n-hexane was prepared, and 0.3 µL was injected using splitless mode [21,22]. GC-FID analysis was performed using an Agilent 7890 gas chromatograph with a type HP-5 fused silica capillary column (30 m × 0.25 mm with film thickness of 0.25 microns, Agilent Technologies, USA).…”
Section: Gc-ms and Gc-fid Analysismentioning
confidence: 99%