2022
DOI: 10.30744/brjac.2179-3425.tn-108-2021
|View full text |Cite
|
Sign up to set email alerts
|

Chemical Characterization in the Production Chain of Permanent Magnets by Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES) – Precise Quantification of Nd, Pr, Fe and B in Super-Magnets Samples

Abstract: Super-magnets, materials whose strong magnetic activity is an attractive differential for the high-tech industry, may have their magnetic performance affected by small variations in their chemical composition. For example, the neodymium and praseodymium content can change the physicochemical properties of the permanent magnets. Aiming at a strict chemical quality control, this work developed an analytical method to quantify the major elements in the materials involved in the production process of didymium (the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…An iCAP 7400 Duo ICP optical emission spectrometer (ThermoFisher Scientic, Cambridge, England) equipped with dual view (axial and radial) plasma was used as a reference. 31 The spectrometer was equipped with a charge injection device (CID) detector array (166.25 to 847.00 nm detection range), and an argon-purged Echelle polychromator. The sample introduction system was a cyclonic spray chamber with a Meinhard nebulizer.…”
Section: Instrumentationmentioning
confidence: 99%
See 2 more Smart Citations
“…An iCAP 7400 Duo ICP optical emission spectrometer (ThermoFisher Scientic, Cambridge, England) equipped with dual view (axial and radial) plasma was used as a reference. 31 The spectrometer was equipped with a charge injection device (CID) detector array (166.25 to 847.00 nm detection range), and an argon-purged Echelle polychromator. The sample introduction system was a cyclonic spray chamber with a Meinhard nebulizer.…”
Section: Instrumentationmentioning
confidence: 99%
“…Reference values were established by ICP OES analysis aer sample dissolution. 31 About 0.5 g of each calcined sample were accurately weighed into a 50 mL conical polypropylene tube (Falcon, Corning™) and mixed with 15 mL of 25% w/v nitric acid and 5 mL of 27% w/v hydrochloric acid and le at room temperature until complete dissolution (ca. 4 h).…”
Section: Sample Preparationmentioning
confidence: 99%
See 1 more Smart Citation