2014
DOI: 10.1016/j.elspec.2014.07.010
|View full text |Cite
|
Sign up to set email alerts
|

Chemical bonding and valence state of 3d-metal ions in Ni 1−x Co x Cr 2 O 4 spinels from X-ray diffraction and X-ray photoelectron spectroscopy data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 33 publications
1
5
0
Order By: Relevance
“…At low temperatures, the з+ ratio between Fe2+: Fe3+ should be 1:2 [32]. In [34] the same shoulder in Ni2p3/2 spectrum was explained by the presence of divalent and trivalent nickel ions in N i1-xCoxCr2O4 spinel structure, and the shoulder formed by the contribution from divalent nickel ions. If this approach is applicable to magnetite in respect to the explanation of the shoulder in Fe2p3/2 spectrum, the contribution of Fe ions into total Fe2p spectrum is higher in Sm:MNPs-Bpy than in Sm:MNPs.…”
Section: Resultsmentioning
confidence: 87%
“…At low temperatures, the з+ ratio between Fe2+: Fe3+ should be 1:2 [32]. In [34] the same shoulder in Ni2p3/2 spectrum was explained by the presence of divalent and trivalent nickel ions in N i1-xCoxCr2O4 spinel structure, and the shoulder formed by the contribution from divalent nickel ions. If this approach is applicable to magnetite in respect to the explanation of the shoulder in Fe2p3/2 spectrum, the contribution of Fe ions into total Fe2p spectrum is higher in Sm:MNPs-Bpy than in Sm:MNPs.…”
Section: Resultsmentioning
confidence: 87%
“…In the Fe2p-spectrum of Fe 2+ ion calculation gives excessive intensity in the energy region between 2p 3/2 satellite and 2p 1/2 main peak. As discussed in [20], this spectral region contains contributions from the correlation states with excitations of more than one ligand electron. Their contributions seem to be overestimated in our calculation.…”
Section: Consideration Only Of Interaction (A) Is An Isolated-ion Appmentioning
confidence: 98%
“…Table 2 shows that the formula composition determined in x-ray microanalysis demonstrates lower content of cadmium in the Pr 1−x Cd x MnO 3 and La 1−x Cd x MnO 3 samples compared to the XPS data. Factors that determine the difference between the data from XPS and EDS methods in terms of determining elemental compositions are discussed in detail in [34]. Three main factors are pointed out in those works: the difference in the diameters of the electron probe (EDS) and x-ray beam spot diameter (XPS), different depth of analysis, and the fact that during scribing, the surface is destroyed and there are either grain bodies or their boundaries on the surface.…”
Section: X-ray Photoelectron Spectroscopymentioning
confidence: 99%
“…We believe that in our case, in addition to the first two factors mentioned above, two additional factors can play a significant role in the increased cadmium content based on the XPS data. One of them partially coincides with the third factor mentioned in [34]. In the XPS method, the surface under study is scribed using a diamond file before analysis, until the O1s spectrum contains only a component related to oxygen embedded in the lattice [33][34][35].…”
Section: X-ray Photoelectron Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation