2002
DOI: 10.1109/tie.2002.803213
|View full text |Cite
|
Sign up to set email alerts
|

Charge balance control schemes for cascade multilevel converter in hybrid electric vehicles

Abstract: Index Terms-Cascade inverter, hybrid electric vehicle, motor drive, multilevel converter, multilevel inverter.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
128
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 320 publications
(131 citation statements)
references
References 16 publications
0
128
0
Order By: Relevance
“…In this control method, each switching device needs only to be switched one time per fundamental cycle, which results in low switching losses and low electromagnetic interference. With N CHB cells, a multilevel inverter under staircase modulation has N arbitrary switching angles for synthesizing the output voltage waveform [25], [28]. Fig.…”
Section: Charge Balance Control Methods For Symmetric Cascaded Mumentioning
confidence: 99%
See 1 more Smart Citation
“…In this control method, each switching device needs only to be switched one time per fundamental cycle, which results in low switching losses and low electromagnetic interference. With N CHB cells, a multilevel inverter under staircase modulation has N arbitrary switching angles for synthesizing the output voltage waveform [25], [28]. Fig.…”
Section: Charge Balance Control Methods For Symmetric Cascaded Mumentioning
confidence: 99%
“…It is important to note that different control methods for the voltage balancing of other types of multilevel inverters have been presented in [18]- [24]. A charge balance control method for symmetric cascaded multilevel inverters has been presented in [25]. This control strategy is based on the rotation of the duty cycles between different H-bridges in such a way that after some fundamental cycles, the average duty cycle of the H-bridges will be equal.…”
Section: Introductionmentioning
confidence: 99%
“…The desired output of a multilevel inverter is synthesized by several sources of DC voltages. Some of the fundamental multilevel topologies include the diodeclamped [2][3][4], flying capacitor [4][5][6], and cascaded Hbridge structures [7][8][9][10]. Several combinatorial designs have also emerged by means of cascading the fundamental topologies that they are called hybrid topologies [10][11][12].…”
Section: Introductionmentioning
confidence: 99%
“…There are several types of multilevel inverters; cascaded H-bridge [6][7][8], neutral-point-clamped, flying capacitor [9][10][11], and the others [12][13][14]. Particularly, cascaded H-bridge inverters have been focused inthese topologies because of the modularity and the simplicity [8].…”
Section: Introductionmentioning
confidence: 99%